RE SERIES MARINE E4 ELECTRIC FRYERS
CHAPTER 2: INSTALLATION INSTRUCTIONS
2.1Introduction
The instructions in this chapter cover all configurations of RE Series Marine Electric Fryer models specifically configured for use aboard surface ships, including FPRE117 kW and FPRE217 kW models. The instructions do not cover and may not be used for installations ashore.
Proper installation is essential for the safe, efficient,
NOTICE
All fryers shipped without factory supplied cords and plug assemblies must be hardwired using flexible conduit to the terminal block located on the rear of the fryer. These fryers should be wired to NEC specifications. Hardwired units must include installation of restraint devices.
DANGER
Adequate means must be provided to limit the movement of this appliance without depending on or transmitting stress to the electrical conduit.
NOTICE
If this equipment is wired directly into the electrical power supply, a means for disconnection from the supply having a contact separation of at least
NOTICE
This equipment must be positioned so that the plug is accessible unless other means for disconnection from the power supply (e.g., a circuit breaker) is provided.
NOTICE
If this appliance is permanently connected to fixed wiring, it must be connected by means of copper wires having a temperature rating of not less than 167°F (75°C).
NOTICE
If the electrical power supply cord is damaged, it must be replaced by a Frymaster Dean Factory Authorized Service Center technician or a similarly qualified person in order to avoid a hazard.
DANGER
This appliance must be connected to a power supply having the same voltage and phase as specified on the rating plate located on the inside of the appliance door.