Jenn-Air W10274320C, LI3UUB Venting Requirements, vented models only, Cold Weather Installations

Page 6
Venting Requirements

Venting Requirements

(vented models only)

Vent system must terminate to the outdoors, except for non-

 

vented (recirculating) installations.

Do not terminate the vent system in an attic or other enclosed

Roof Venting

Wall Venting
Non-vented

 

 

(recirculating)

area.

Do not use 4" (10.2 cm) laundry-type wall cap.

Use metal vent only. Rigid metal vent is recommended.

Plastic or metal foil vent is not recommended.

The length of vent system and number of elbows should be

kept to a minimum to provide efficient performance.

For the most efficient and quiet operation:

Use no more than three 90° elbows.

Make sure there is a minimum of 24" (61 cm) of straight vent

between the elbows if more than 1 elbow is used.

Do not install 2 elbows together.

Use clamps to seal all joints in the vent system.

The vent system must have a damper. If the roof or wall cap

B

AA

B (vented models only)

B

A

has a damper, do not use the damper supplied with the range

hood.

Use caulking to seal exterior wall or roof opening around the

cap.

The size of the vent should be uniform.

Cold Weather Installations

An additional back draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break.

The break should be as close as possible to where the vent system enters the heated portion of the house.

Makeup Air

Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air movement. The specified CFM varies from locale to locale.

Consult your HVAC professional for specific requirements in your area.

A. Roof cap

A. Wall cap

A. Deflector

B. 6" (15.2 cm)

B. 6" (15.2 cm)

B. 6" (15.2 cm)

round vent

round vent

round vent

Calculating Vent System Length

To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.

Vent Piece
6" (15.2 cm) Round

45° elbow

2.5 ft

 

(0.8 m)

90° elbow

5.0 ft

 

(1.5 m)

Maximum equivalent vent length is 35 ft (10.7 m).

Venting Methods

This canopy hood is factory set for venting through the roof or wall.

A 6" (15.2 cm) round vent system is needed for installation (not included). The hood exhaust opening is 6" (15.2 cm) round.

NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduce performance.

Vent system can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed.

Rear discharge

A 90° elbow may be installed immediately above the hood.

For Non-Vented (recirculating) Installations

If it is not possible to vent cooking fumes and vapors to the outside, the hood can be used in the non-vented (recirculating) version, fitting a charcoal filter and the deflector. Fumes and vapors are recycled through the top grille.

Example vent system

90 elbow

 

 

 

 

 

 

Wall cap

 

 

6 ft (1.8 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2ft

(0.6 m)

The following example falls within the maximum recommended vent length of 35 ft (10.7 m).

1

- 90° elbow

= 5.0 ft (1.5 m)

1

- wall cap

= 0.0 ft (0.0 m)

8 ft (2.4 m) straight

= 8.0 ft (2.4 m)

 

 

Length of system

= 13.0 ft (3.9 m)

 

 

 

6

Image 6
Contents LI3UUB/W10274320C Installation Instructions and Use & Care GuideInstructions d’installation et Guide d’utilisation et d’entretien Table of Contents/Table des matièresINSTALLATION REQUIREMENTS TABLE OF CONTENTSRANGE HOOD SAFETY INSTALLATION INSTRUCTIONSRANGE HOOD SAFETY Your safety and the safety of others are very importantDANGER READ AND SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONSINSTALLATION REQUIREMENTS Tools and PartsCabinet Dimensions Product DimensionsFor Mobile Home Installations For vented installations, you will also needVenting Requirements Cold Weather InstallationsFor Non-Vented recirculating Installations vented models onlySAVE THESE INSTRUCTIONS Electrical RequirementsGROUNDING INSTRUCTIONS Electrical Shock Hazard Plug into a grounded 3 prong outletVent Cover Support Bracket Installation INSTALLATION INSTRUCTIONSRange Hood Mounting Screws Installation Excessive Weight HazardFor non-vented recirculating installation only Install Range HoodFor vented installations only Connect Vent SystemGrease Filter Saturation Alarm Install Vent CoversComplete Installation RANGE HOOD USEAudible Signal Activation and Deactivation TimerCharcoal Filter Saturation Alarm Charcoal Filter Recirculation Accessory Inclusion and ExclusionCleaning Method CleaningNon-Vented recirculating Installation Filters RANGE HOOD CARES3 S2 S1 WIRING DIAGRAMSE1X5A Electronic User InterfaceIf you need replacement parts ASSISTANCE OR SERVICEAccessories In the U.S.AITEMS EXCLUDED FROM WARRANTY This limited warranty does not cover JENN-AIR MAJOR APPLIANCE WARRANTYONE YEAR LIMITED WARRANTY DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIESPage SÉCURITÉ DE LA HOTTE DE CUISINIÈRE DANGER AVERTISSEMENTVotre sécurité et celle des autres est très importante IMPORTANTES INSTRUCTIONS DE SÉCURITÉ LIRE ET CONSERVER CES INSTRUCTIONSInstallation dans une résidence mobile EXIGENCES DINSTALLATIONExigences d’emplacement Dimensions du produitExigences concernant l’évacuation Dimensions du placardInstallation dans une région à climat froid seulement pour un modèle avec décharge à lextérieurMéthodes d’évacuation Installation sans décharge à lextérieur recyclageInstallation sans Décharge par larrièreINSTRUCTIONS DE MISE À LA TERRE AVERTISSEMENTSpécifications électriques CONSERVEZ CES INSTRUCTIONSInstallation des vis de montage de la hotte INSTRUCTIONS DINSTALLATIONPréparation de lemplacement Installation de la bride de cache-conduitInstallations sans décharge à lextérieur recyclage uniquement Installation de la hotteInstallations avec décharge à l’extérieur uniquement Raccordement du circuit dévacuationTableau de commande Installation des cache-conduitsAchever l’installation Alarme de saturation du filtre à graisseInclusion et exclusion du filtre à charbon accessoire de recyclage Alarme de saturation du filtre à charbonActivation et désactivation du signal sonore Power Increase/On augmentation de la puissance/ activéRemplacement du filtre à charbon Filtres dinstallation sans décharge à l’extérieur recyclageRemplacement d’une lampe à halogène ENTRETIEN DE LA HOTTESCHÉMA DE CÂBLAGE Tableau dalimentationAu Canada ASSISTANCE OU SERVICEAccessoires Si vous avez besoin de pièces de rechangeARTICLES EXCLUS DE LA GARANTIE GARANTIE DES GROS APPAREILS MÉNAGERS JENN-AIRGARANTIE LIMITÉE DE UN AN La présente garantie limitée ne couvre pasPage 12/09 W10274320C2009 All rights reserved