Jenn-Air LI3UUB Location Requirements, Parts needed, Product Dimensions, Parts supplied

Page 5
Parts needed

Parts needed

For vented installations, you will also need:

1 wall or roof cap

Metal vent system

For non-vented (recirculating) installations, you will also need:

Recirculation Kit Part Number W10272063 for non-vented

(recirculating) installations only. See “Assistance or Service”

section to order.

Product Dimensions

8¹⁄₁₆" 8¹⁄₈"

(20.4 cm) (20.7 cm)

*28¹⁵⁄₁₆" (73.4 cm) min.

6" (15.2 cm) dia. round metal vent duct - length required is

14¹⁄₈"

42³⁄₁₆" (107.2 cm) max.

determined by ceiling height.

Parts supplied

Remove parts from packages. Check that all parts are included.

Hood canopy assembly with ventilator and light bulbs

 

installed

Vent transition with back draft dampers installed

Metal grease filter(s)

36" (91.4 cm)

(35.9 cm)

**28⁷⁄₈" (73.3 cm) min. 38⁷⁄₁₆" (97.6 cm) max.

10¹⁄₈"

(25.8 cm)

20" (50.8 cm)

Vent cover support bracket

Mounting template

2-piece vent cover

2 - 3.5 x 6.5 mm screws

2

- 2.9 x 6.5 mm screws

6

- 5 x 45 mm mounting screws

2

- 8 x 40 mm wall anchors

4

- 10 x 50 mm wall anchors

 

 

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

Have a qualified technician install the range hood. It is the installer's responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located behind the left filter on the rear wall of the vent hood.

Canopy hood location should be away from strong draft areas, such as windows, doors and strong heating vents.

Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance.

Grounded electrical outlet is required. See “Electrical Requirements” section.

The canopy hood is factory set for venting through the roof or wall. For non-vented (recirculating) Installation see “For Non- vented (recirculating) Installations Only” in “Connect Vent System” section. Recirculation Kit Part Number W10272063 is available from your dealer or an authorized parts distributor.

All openings in ceiling and wall where canopy hood will be installed must be sealed.

For Mobile Home Installations

The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local codes.

*For non-vented (recirculating) installations

**For vented installations

Cabinet Dimensions

7¹⁄₄" (18.4 cm)

2" (5.1 cm) min. 6" (15.2 cm) min.*

6⁵⁄₈" (16.8 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vent and power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7³⁄₈" (18.8 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

supply cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

entry location

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15" (38.1 cm)

 

Side

 

 

 

 

 

 

 

 

 

Side

 

cabinet

 

 

 

 

 

 

 

 

 

cabinet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36" (91.4 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"X"

bottom of

canopy

to cooking surface

Centerline

Cooking surface

*For non-vented (recirculating) installations

*NOTE: The range hood chimneys are adjustable and designed to meet varying ceiling or soffit heights depending on the distance “X” between the bottom of the range hood and the cooking surface. For higher ceilings, a Stainless Steel Chimney Extension Kit Part Number W10272070 is available from your dealer or an authorized parts distributor. The chimney extension replaces the upper chimney shipped with the range hood.

IMPORTANT:

Minimum distance "X": 27" (68.6 cm) from electric cooking surface.

Minimum distance "X": 30" (76.2 cm) from gas cooking surfaces.

Suggested maximum distance "X": 36" (91.4 cm)

For vented installations, the chimneys can be adjusted for ceilings between 7’ 11" (2.4 m) and 8' 8" (2.6 m).

For non-vented (recirculating) installations, the chimneys can be adjusted for ceilings between 7’ 11" (2.4 m) and 9' 0" (2.7 m).

5

Image 5
Contents Instructions d’installation et Guide d’utilisation et d’entretien Installation Instructions and Use & Care GuideLI3UUB/W10274320C Table of Contents/Table des matièresRANGE HOOD SAFETY TABLE OF CONTENTSINSTALLATION REQUIREMENTS INSTALLATION INSTRUCTIONSDANGER RANGE HOOD SAFETYYour safety and the safety of others are very important INSTALLATION REQUIREMENTS IMPORTANT SAFETY INSTRUCTIONSREAD AND SAVE THESE INSTRUCTIONS Tools and PartsFor Mobile Home Installations Product DimensionsCabinet Dimensions For vented installations, you will also needFor Non-Vented recirculating Installations Cold Weather InstallationsVenting Requirements vented models onlyGROUNDING INSTRUCTIONS Electrical RequirementsSAVE THESE INSTRUCTIONS Electrical Shock Hazard Plug into a grounded 3 prong outletRange Hood Mounting Screws Installation INSTALLATION INSTRUCTIONSVent Cover Support Bracket Installation Excessive Weight HazardFor vented installations only Install Range HoodFor non-vented recirculating installation only Connect Vent SystemComplete Installation Install Vent CoversGrease Filter Saturation Alarm RANGE HOOD USECharcoal Filter Saturation Alarm TimerAudible Signal Activation and Deactivation Charcoal Filter Recirculation Accessory Inclusion and ExclusionNon-Vented recirculating Installation Filters CleaningCleaning Method RANGE HOOD CARESE1X5A WIRING DIAGRAMS3 S2 S1 Electronic User InterfaceAccessories ASSISTANCE OR SERVICEIf you need replacement parts In the U.S.AONE YEAR LIMITED WARRANTY JENN-AIR MAJOR APPLIANCE WARRANTYITEMS EXCLUDED FROM WARRANTY This limited warranty does not cover DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIESPage Votre sécurité et celle des autres est très importante SÉCURITÉ DE LA HOTTE DE CUISINIÈREDANGER AVERTISSEMENT LIRE ET CONSERVER CES INSTRUCTIONS IMPORTANTES INSTRUCTIONS DE SÉCURITÉExigences d’emplacement EXIGENCES DINSTALLATIONInstallation dans une résidence mobile Dimensions du produitInstallation dans une région à climat froid Dimensions du placardExigences concernant l’évacuation seulement pour un modèle avec décharge à lextérieurInstallation sans Installation sans décharge à lextérieur recyclageMéthodes d’évacuation Décharge par larrièreSpécifications électriques AVERTISSEMENTINSTRUCTIONS DE MISE À LA TERRE CONSERVEZ CES INSTRUCTIONSPréparation de lemplacement INSTRUCTIONS DINSTALLATIONInstallation des vis de montage de la hotte Installation de la bride de cache-conduitInstallations avec décharge à l’extérieur uniquement Installation de la hotteInstallations sans décharge à lextérieur recyclage uniquement Raccordement du circuit dévacuationAchever l’installation Installation des cache-conduitsTableau de commande Alarme de saturation du filtre à graisseActivation et désactivation du signal sonore Alarme de saturation du filtre à charbonInclusion et exclusion du filtre à charbon accessoire de recyclage Power Increase/On augmentation de la puissance/ activéRemplacement d’une lampe à halogène Filtres dinstallation sans décharge à l’extérieur recyclageRemplacement du filtre à charbon ENTRETIEN DE LA HOTTETableau dalimentation SCHÉMA DE CÂBLAGEAccessoires ASSISTANCE OU SERVICEAu Canada Si vous avez besoin de pièces de rechangeGARANTIE LIMITÉE DE UN AN GARANTIE DES GROS APPAREILS MÉNAGERS JENN-AIRARTICLES EXCLUS DE LA GARANTIE La présente garantie limitée ne couvre pasPage 2009 W10274320C12/09 All rights reserved