Jenn-Air LI3UUB Install Range Hood, Connect Vent System, A B C, For vented installations only

Page 9
Install Range Hood

Install Range Hood

1.Using 2 or more people, hang range hood on 2 mounting screws through the mounting slots on back of hood.

A

AB

C

A. Mounting screws

B. Mounting slots

C. Lower mounting screws

2.Remove the grease filter. See “Range Hood Care” section.

3.Level the range hood and tighten upper mounting screws.

4.Install 2 - 5 x 45 mm lower mounting screws and tighten.

Connect Vent System

1.Install transition on top of hood (if removed for shipping) with 2 - 3.5 x 6.5 mm sheet metal screws.

A

B

A. Vent transition

B. 3.5 x 6.5 mm screw

For vented installations only:

1.Fit vent system over transition piece.

2.Seal connection with clamps.

3.Check that back draft dampers work properly.

For non-vented (recirculating) installation only:

1.Assemble the air deflector with the duct cover bracket with 2 - assembly screws provided with the Recirculation Kit.

B Connect Vent System A

B

C

A. Vent cover bracket

B. 2.9 x 6.5 mm screws

C.Deflector

2.Measure from the bottom of the air deflector to the bottom of the hood outlet.

A

B

X C

D

E

A. Air deflector

B. Vent clamp

C. X = length to cut vent duct

D. Vent duct

E. Exhaust outlet

3.Cut the duct to the measured size (X).

4.Remove the air deflector.

5.Slide the duct onto the bottom of the air deflector.

6.Place the assembled air deflector and duct over the exhaust outlet from the hood.

7.Reassemble the air deflector to the duct cover bracket with 2 assembly screws.

9

Image 9
Contents Instructions d’installation et Guide d’utilisation et d’entretien Installation Instructions and Use & Care GuideLI3UUB/W10274320C Table of Contents/Table des matièresRANGE HOOD SAFETY TABLE OF CONTENTSINSTALLATION REQUIREMENTS INSTALLATION INSTRUCTIONSRANGE HOOD SAFETY Your safety and the safety of others are very importantDANGER INSTALLATION REQUIREMENTS IMPORTANT SAFETY INSTRUCTIONSREAD AND SAVE THESE INSTRUCTIONS Tools and PartsFor Mobile Home Installations Product DimensionsCabinet Dimensions For vented installations, you will also needFor Non-Vented recirculating Installations Cold Weather InstallationsVenting Requirements vented models onlyGROUNDING INSTRUCTIONS Electrical RequirementsSAVE THESE INSTRUCTIONS Electrical Shock Hazard Plug into a grounded 3 prong outletRange Hood Mounting Screws Installation INSTALLATION INSTRUCTIONSVent Cover Support Bracket Installation Excessive Weight HazardFor vented installations only Install Range HoodFor non-vented recirculating installation only Connect Vent SystemComplete Installation Install Vent CoversGrease Filter Saturation Alarm RANGE HOOD USECharcoal Filter Saturation Alarm TimerAudible Signal Activation and Deactivation Charcoal Filter Recirculation Accessory Inclusion and ExclusionNon-Vented recirculating Installation Filters CleaningCleaning Method RANGE HOOD CARESE1X5A WIRING DIAGRAMS3 S2 S1 Electronic User InterfaceAccessories ASSISTANCE OR SERVICEIf you need replacement parts In the U.S.AONE YEAR LIMITED WARRANTY JENN-AIR MAJOR APPLIANCE WARRANTYITEMS EXCLUDED FROM WARRANTY This limited warranty does not cover DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIESPage SÉCURITÉ DE LA HOTTE DE CUISINIÈRE DANGER AVERTISSEMENTVotre sécurité et celle des autres est très importante LIRE ET CONSERVER CES INSTRUCTIONS IMPORTANTES INSTRUCTIONS DE SÉCURITÉExigences d’emplacement EXIGENCES DINSTALLATIONInstallation dans une résidence mobile Dimensions du produitInstallation dans une région à climat froid Dimensions du placardExigences concernant l’évacuation seulement pour un modèle avec décharge à lextérieurInstallation sans Installation sans décharge à lextérieur recyclageMéthodes d’évacuation Décharge par larrièreSpécifications électriques AVERTISSEMENTINSTRUCTIONS DE MISE À LA TERRE CONSERVEZ CES INSTRUCTIONSPréparation de lemplacement INSTRUCTIONS DINSTALLATIONInstallation des vis de montage de la hotte Installation de la bride de cache-conduitInstallations avec décharge à l’extérieur uniquement Installation de la hotteInstallations sans décharge à lextérieur recyclage uniquement Raccordement du circuit dévacuationAchever l’installation Installation des cache-conduitsTableau de commande Alarme de saturation du filtre à graisseActivation et désactivation du signal sonore Alarme de saturation du filtre à charbonInclusion et exclusion du filtre à charbon accessoire de recyclage Power Increase/On augmentation de la puissance/ activéRemplacement d’une lampe à halogène Filtres dinstallation sans décharge à l’extérieur recyclageRemplacement du filtre à charbon ENTRETIEN DE LA HOTTETableau dalimentation SCHÉMA DE CÂBLAGEAccessoires ASSISTANCE OU SERVICEAu Canada Si vous avez besoin de pièces de rechangeGARANTIE LIMITÉE DE UN AN GARANTIE DES GROS APPAREILS MÉNAGERS JENN-AIRARTICLES EXCLUS DE LA GARANTIE La présente garantie limitée ne couvre pasPage 2009 W10274320C12/09 All rights reserved