module will not energize the second main valve, and the main burner will not light. The S8600F, which is used on natural gas fryers, will continue to spark as long as the fryer’s thermostat calls for heat or until the pilot lights.
The S8600H, which is used on propane fryers, provides 100 percent shutoff and safety lockout. Its ignition sparks only for a
2.Set the fryer’s thermostat above 200°F/93°C.
Watch to see whether there is a spark at the pilot burner immediately.
3.Time the spark from the time it starts to the time it shuts off.
4.Compare this time with the shutoff time that is stamped on the module. They should be the same.
5.Open the manual gas cock and make sure that no gas is flowing to the pilot or main burner.
6.Set the fryer’s thermostat below 200°F/93°C and wait at least one minute before continuing.
Main Burner Operation
When the pilot flame is established, a flame rectification circuit is completed between the sensor and the burner ground. The flame sensing circuit in the module detects the flame current, shuts off the spark generator, and energizes the second main valve operator. The second main valve opens and gas flows to the main burner, where it is ignited by the pilot burner. On the S8600H, the safety lockout timer is held in the normal operating mode.
When the thermostat no longer calls for heat, both valve operators are
Step 3: Reset the Module
1.Turn the thermostat to its lowest setting.
2.Wait at least one minute.
Step 4: Check Safety Shutoff
Operation
This step applies only to the S8600H, which is used on propane fryers.
1.Turn the gas supply off.
Belshaw Bros., Inc. • 1750 22nd Ave. S. • Seattle, WA 98144 • Phone