Extron electronic XPA2001-70V, XPA1002, XPA2001-100V Flexible Conduit Adapter Kit Installation

Page 12

Rack Mounting Ventilation Recommendations

Excessive heat can decrease the optimal lifetime of the power amplifier. An over temp indicator LED on the front panel of the amplifier lights red whenever the recommended operating temperature has been exceeded. See “Front Panel Features and Operation” on page 9.

To reduce the chances for an over temp condition, the XPAs should be arranged in a rack environment so that adequate airflow is available both above and below the XPA whenever possible. No more than two XPAs should be arranged one-on-top-of-the-other in a rack without an open space between them, as shown in the following illustration. An XPA can also be arranged above or below another non-XPA device, but there must be an open space both above and below those devices.

Ve

 

 

 

nt

Space

 

 

Ve

 

 

 

 

 

nt

Space

 

 

Ve

Ve

 

 

nt

Space

nt

Space

 

 

 

Ve

 

 

 

nt

 

nt

Space

Spa

 

Ve

 

 

 

 

 

 

ce

Figure 4. Allow Sufficient Spacing for Adequate Ventilation

Flexible Conduit Adapter Kit Installation

WARNING: Failure to follow these instructions may result in serious injury.

The circuit breaker used for this connection should be rated no lower than 20 amps and no greater than 30 amps.

This unit must be installed in accordance with the National Electrical

Code and with all local codes.

An ALL-POLE MAINS SWITCH with a contact separation of at least

3 mm in each pole shall be incorporated in the electrical installation of the building. The installation shall be carried out in accordance with all applicable installation rules.

Installation and service must be performed by a qualified electrician only.

ATTENTION: Failure to follow these instructions may result in damage to the unit.

A UL listed electrical distribution box is recommended for the termination of the conduit opposite the XPA. See the following “UL Requirements” section on page 7.

The optional Flexible Conduit Adapter Kit (Extron part #70-228-02) consists of

One EMT adapter plate

One 6-foot long electrical conduit

Three 7.5 feet, 18-gauge spade connector power wires

One UL rated zip tie wrap

Three auxiliary crimp style spade connectors designed for 14- to 16-gauge wires

XTRA Series • Installation

6

Image 12
Contents User Guide Safety Instructions English Specifications Availability FCC Class B NoticePage Contents Page Features Continuous power output for larger roomsAbout this Manual Terms Used in this ManualXtra Series Introduction Application Examples XPA 1002 Application ExampleMounting the XPA 1002 and XPA Tabletop UseUL Guidelines for Rack Mounting Rack Mounting Rack Mounting of the AmplifierFlexible Conduit Adapter Kit Installation Allow Sufficient Spacing for Adequate VentilationUL Requirements Removing the IEC Connector Front Panel Features and Operation Power indicator LED This LED lightsLIMITER/PROTECT Rear Panel Features and Operation Attenuation Inputs RemoteInputsinputs See Remote Volume Control on XPA XPA Do not tin the wires Remote Volume Control Controlling Multiple Amplifiers with One Volume Controller Bridged Mono Output Bridging the Output of the XPATroubleshooting Amplifier Fails to Exit Standby Mode PromptlyAmplifier Enters Standby Mode Too Early Limiter/Protect LED Warning Indicators Over Temp Indicator LEDLED State Problem Description Problem Solution Part Numbers and Accessories Optional AccessoriesIncluded parts Replacement Part number Accessories Part numberUSA, Canada, South America Japan Central America Europe and Africa ChinaAsia Middle East Europe