Remote Volume Control
Options for remote control of the XPA amplifiers include the Extron VCM 100 and
VC 50 volume controllers. Third party 10k potentiometer volume controllers can also be connected to this port.
As shown in the following illustration, pin V (1) on the XPA is a 10 VDC reference voltage. Pin C (2) is the volume control DC voltage input. The range is 0 to 10 V, where 0 V is mute and 10 V provides maximum volume. Pin G (3) is ground.
NOTE: All nominal levels are at ±10%.
| REMOTE |
| G STANDBY |
10V | 50mA |
V | C G |
| Red |
| Black |
or | Ground |
10V 50 mA
VOL/MUTE
1 | 2 | 3 | 4 | 5 |
STANDBY
Extron
STP 22
Cable
VOL/ MUTE 10V
VOLUME
MUTE |
VCM 100
Figure 8. Pinout Diagram for VCM 100 MAAP Connection to XPA Remote Connector
XTRA Series • Operation | 17 |