DAttenuation (channels 1 and 2) — Use a small screwdriver to adjust the audio input

level for the corresponding channel. The analog potentiometers control the level from

= (full attenuation) to 0 dB.

NOTES: On the XPA 2001, the single control adjusts the levels of both channels simultaneously prior to summing them together.

On some models, this adjustment is referred to as “level”. The function is the same, whichever way your product is labeled.

To adjust the input level of the XPA amplifier, do the following:

1.If connecting to a source device with a volume control (variable output), ensure that the volume on the source device is set to its lowest point, then adjust the level of the XPA fully counterclockwise.

2.Set the source device’s volume to its maximum volume level. No sound should come out.

3.Return to the XPA amplifier and raise the level until sound distortion occurs, then lower the level slightly until any distortion disappears. This setting ensures that, whatever the source device volume setting may be, no clipping occurs.

NOTE: When setting volume control through a source device, ensure that the volume of the device is set to variable out. Consult the user manual of the device for detailed instructions on its calibration.

ÀBalanced or unbalanced stereo or mono audio input connector (XPA 1002)

Wire the 3.5 mm 5-pin captive screw connector for balanced or unbalanced input.

Tip

L

Tip

Ring

Sleeve

 

Sleeves

Tip

 

Tip

Sleeve

R

Ring

Unbalanced Stereo Input

Balanced Stereo Input

 

 

 

L

Tip

Sleeve

R

Unbalanced Mono Input

L

Tip

 

 

Ring

R

Sleeve

 

Balanced Mono Input

L R

Do not tin the wires!

NOTE: The input connector port may be labeled one of two ways. The wiring and function are the same, whichever way your product is labeled.

INPUTSINPUTS

1

2

1

2

 

 

or

NOTE: The output power of the XPA 1002 can be effectively doubled by using only one input channel and bridging the output. The XPA 1002 will output

200 watts @ 8 ohms in bridged mode. See “Bridged Mono Output” on page 19 for wiring instructions when bridging the XPA 1002.

XTRA Series • Operation

12

Image 18
Contents User Guide Safety Instructions English Specifications Availability FCC Class B NoticePage Contents Page About this Manual FeaturesContinuous power output for larger rooms Terms Used in this ManualXtra Series Introduction Application Examples XPA 1002 Application ExampleMounting the XPA 1002 and XPA Tabletop UseUL Guidelines for Rack Mounting Rack Mounting Rack Mounting of the AmplifierFlexible Conduit Adapter Kit Installation Allow Sufficient Spacing for Adequate VentilationUL Requirements Removing the IEC Connector Front Panel Features and Operation Power indicator LED This LED lightsLIMITER/PROTECT Rear Panel Features and Operation Attenuation Inputs RemoteInputsinputs See Remote Volume Control on XPA XPA Do not tin the wires Remote Volume Control Controlling Multiple Amplifiers with One Volume Controller Bridged Mono Output Bridging the Output of the XPATroubleshooting Amplifier Fails to Exit Standby Mode PromptlyAmplifier Enters Standby Mode Too Early Limiter/Protect LED Warning Indicators Over Temp Indicator LEDLED State Problem Description Problem Solution Included parts Replacement Part number Part Numbers and AccessoriesOptional Accessories Accessories Part numberAsia Middle East USA, Canada, South America Japan Central AmericaEurope and Africa China Europe