Extron electronic XPA1002, XPA2001-70V, XPA2001-100V manual See Remote Volume Control on

Page 19

ÂBalanced or unbalanced stereo or mono audio input connector (XPA 2001)

Wire the 3.5 mm 5-pin captive screw connector for balanced or unbalanced input.

Tip

L

Tip

Ring

Sleeve

 

Sleeves

Tip

 

Tip

Sleeve

R

Ring

Unbalanced Stereo Input

Balanced Stereo Input

L R

Tip

Sleeve

Unbalanced Mono Input

L

Tip

 

 

Ring

R

Sleeve

 

Balanced Mono Input

L R

Do not tin the wires!

NOTE: The input connector port may be labeled one of two ways. The wiring and function are the same, whichever way your product is labeled.

INPUTSINPUTS

L(MONO) R

L (SUMMED) R

or

NOTE: For mono input on the XPA 2001, because the left and right channels are summed, only the left channel needs to be wired. No jumpering to the right channel is needed.

FRemote control connector — The 3.5 mm 5-pin captive screw receptacle is used to remotely control two functions through contact closure: See the following circuit diagram.

NOTE: The remote control port may be labeled one of two ways (see the following images). The wiring and function are the same, whichever way your product is labeled.

Pins V, C, and G (1, 2, and 3) control volume by varying the DC voltage from 0 V (full attenuation) to 10 V (maximum volume) with full muting in effect when pin C is connected to ground (pin G). Use the included 3-pin captive screw connector.

See “Remote Volume Control” on page 17.

 

REMOTE

 

G STANDBY

10V

50mA

V

C G

MAX

2K OHMS

10K OHMS

MIN

10V 50 mA

VOL/MUTE

or

1

2

3

4

5

STANDBY

1 V

2 C

MUTE SWITCH

3 G

MUTE

VOLUME

XTRA Series • Operation

13

Image 19
Contents User Guide Safety Instructions English FCC Class B Notice Specifications AvailabilityPage Contents Page Terms Used in this Manual FeaturesContinuous power output for larger rooms About this ManualXtra Series Introduction XPA 1002 Application Example Application ExamplesTabletop Use Mounting the XPA 1002 and XPAUL Guidelines for Rack Mounting Rack Mounting of the Amplifier Rack MountingAllow Sufficient Spacing for Adequate Ventilation Flexible Conduit Adapter Kit InstallationUL Requirements Removing the IEC Connector Power indicator LED This LED lights Front Panel Features and OperationLIMITER/PROTECT Attenuation Inputs Remote Rear Panel Features and OperationInputsinputs See Remote Volume Control on XPA XPA Do not tin the wires Remote Volume Control Controlling Multiple Amplifiers with One Volume Controller Bridging the Output of the XPA Bridged Mono OutputAmplifier Fails to Exit Standby Mode Promptly TroubleshootingAmplifier Enters Standby Mode Too Early Over Temp Indicator LED Limiter/Protect LED Warning IndicatorsLED State Problem Description Problem Solution Accessories Part number Part Numbers and AccessoriesOptional Accessories Included parts Replacement Part numberEurope USA, Canada, South America Japan Central AmericaEurope and Africa China Asia Middle East