Extron electronic XPA2001-70V Limiter/Protect LED Warning Indicators, Over Temp Indicator LED

Page 27

Limiter/Protect LED Warning Indicators

The output channel (channels 1 and 2) Limiter/Protect LED lights red per indicated output channel as shown in the following diagnostic information.

LED State

Problem Description

Problem Solution

Blinks

Audio clipping is occurring at the

Reduce the power output to

 

rate of one blink per clip.

avoid overdriving the amplifier

 

 

and causing clipping.

Lights steady

The amplifier may be overheating.

Determine the reason for the

 

 

overheated state and allow the

 

 

amplifier to cool. The LED will not

 

 

be lit after the amplifier recovers

 

 

from the overheated state.

 

 

 

 

Output channel leads are shorted

Check speakers and speaker

 

 

wiring for shorts.

Over Temp Indicator LED

This indicator does not represent a hard failure of the unit. It is meant as a warning that the amplifier has exceeded the recommended operating temperature for optional product lifetime.

LED State

Problem Description

Problem Solution

Lights steady

Amplifier has exceeded the

Verify that the placement of the

 

recommended operating

 

amplifier allows for adequate

 

temperature. The LED turns off

 

ventilation and airflow.

 

after the amplifier cools down

Avoid placing equipment on top

 

sufficiently.

 

 

of the amplifier.

 

 

 

 

 

Verify that the operating

 

 

 

temperature is within the

 

 

 

specified range.

XTRA Series • Troubleshooting

21

Image 27
Contents User Guide Safety Instructions English FCC Class B Notice Specifications AvailabilityPage Contents Page Terms Used in this Manual FeaturesContinuous power output for larger rooms About this ManualXtra Series Introduction XPA 1002 Application Example Application ExamplesMounting the XPA 1002 and XPA Tabletop UseUL Guidelines for Rack Mounting Rack Mounting of the Amplifier Rack MountingAllow Sufficient Spacing for Adequate Ventilation Flexible Conduit Adapter Kit InstallationUL Requirements Removing the IEC Connector Power indicator LED This LED lights Front Panel Features and OperationLIMITER/PROTECT Attenuation Inputs Remote Rear Panel Features and OperationInputsinputs See Remote Volume Control on XPA XPA Do not tin the wires Remote Volume Control Controlling Multiple Amplifiers with One Volume Controller Bridging the Output of the XPA Bridged Mono OutputTroubleshooting Amplifier Fails to Exit Standby Mode PromptlyAmplifier Enters Standby Mode Too Early Limiter/Protect LED Warning Indicators Over Temp Indicator LEDLED State Problem Description Problem Solution Accessories Part number Part Numbers and AccessoriesOptional Accessories Included parts Replacement Part numberEurope USA, Canada, South America Japan Central AmericaEurope and Africa China Asia Middle East