Extron electronic XPA2001-100V, XPA2001-70V, XPA1002 manual Xpa

Page 20

Pin 5 connected to ground (pin 4) places the amplifier in standby mode. Standby mode turns off all output, although the amplifier is still receiving power. Use the included 2-pin, 3.5 mm captive screw connector to remotely ground pin 5.

The power indicator LED lights amber when the amplifier is in standby mode.

 

REMOTE

 

G STANDBY

10V

50mA

V C G

or

10V 50 mA

VOL/MUTE

1

2

3

4

5

STANDBY

V

 

10V

C G

G

50mA

 

STANDBY

Remote Switching to Standby Mode

ÅStereo audio output connector (channels 1 and 2) — Marked “1” and “2” for the output channels, wire the included 4-pole, 5 mm screw lock captive screw connector to output stereo audio. Observe the correct polarities for each channel. See the following steps. The output is designed to power 4 or 8 ohm speakers and is rated at 100 watts per channel at 4 ohms and 60 watts per channel at 8 ohms.

NOTES: You must use Class 2 wiring for this output to comply with UL requirements.

The stereo audio output connector may be labeled one of two ways (see the images below). The wiring and function are the same, whichever way your product is labeled.

8Ω/4Ω OUTPUTS

 

1

2

1OUTPUT2

CLASS 2 WIRING

or

XPA 1002

ATTENTION: Failure to follow these instructions may result in damage to the unit.

Do not tie channel outputs 1 and 2 to each other or to ground. Doing so will short out the outputs and/or damage the amplifier.

NOTE: The output power of the XPA 1002 can be effectively doubled by using only one input channel and bridging the output. The XPA 1002 will output 200 watts at 8 ohms in bridged mode. See “Bridged Mono Output” on page 19 for wiring instructions when bridging the XPA 1002.

XTRA Series • Operation

14

Image 20
Contents User Guide Safety Instructions English Specifications Availability FCC Class B NoticePage Contents Page Features Continuous power output for larger roomsAbout this Manual Terms Used in this ManualXtra Series Introduction Application Examples XPA 1002 Application ExampleUL Guidelines for Rack Mounting Mounting the XPA 1002 and XPATabletop Use Rack Mounting Rack Mounting of the AmplifierFlexible Conduit Adapter Kit Installation Allow Sufficient Spacing for Adequate VentilationUL Requirements Removing the IEC Connector Front Panel Features and Operation Power indicator LED This LED lightsLIMITER/PROTECT Rear Panel Features and Operation Attenuation Inputs RemoteInputsinputs See Remote Volume Control on XPA XPA Do not tin the wires Remote Volume Control Controlling Multiple Amplifiers with One Volume Controller Bridged Mono Output Bridging the Output of the XPAAmplifier Enters Standby Mode Too Early TroubleshootingAmplifier Fails to Exit Standby Mode Promptly LED State Problem Description Problem Solution Limiter/Protect LED Warning IndicatorsOver Temp Indicator LED Part Numbers and Accessories Optional AccessoriesIncluded parts Replacement Part number Accessories Part numberUSA, Canada, South America Japan Central America Europe and Africa ChinaAsia Middle East Europe