Extron electronic XPA2001-70V, XPA1002 Controlling Multiple Amplifiers with One Volume Controller

Page 24

Controlling Multiple Amplifiers with One Volume Controller

Several XPA 1002 and XPA 2001 units can be daisy-chained so that one volume controller can simultaneously regulate the volume of all the amplifiers.

NOTES: As additional amplifiers are added to the daisy chain, the sensitivity of the volume potentiometer will change. The maximum volume level (fully clockwise) will not be affected. However, the effectiveness of the minimum volume level (fully counterclockwise) in reducing the volume to inaudible

levels decreases as more amplifiers are added to the daisy chain.

When more than two XPA Half-Rack units are attached to the chain, sound may be heard even if the levels have been set to their lowest. The muting of the output, however, can be remedied with a contact closure button attached between the Vol/Mute and the Ground pin of the first

XPA Half-Rack unit in the chain.

To regulate multiple amplifiers with a single volume controller:

1.Attach all three pins of the volume controller to the corresponding pins on the first

XPA Half-Rack unit only — Ground to G (ground), Vol/Mute to C (Vol/Mute), and 10 V to V (10 V).

2.Use jumper wires to connect the C (Vol/Mute) pins of the first amplifier and each successive amplifier.

3.Use jumper wires to connect the G (ground) pins of the first amplifier and each successive amplifier.

Extron

VCM 100 AAP

VOL/ MUTE 10V

 

REMOTE

 

G STANDBY

10V

50mA

V

C G

Extron

XPA Half-Rack daisy chain

 

REMOTE

 

G STANDBY

10V

50mA

V

C G

 

REMOTE

 

G STANDBY

10V

50mA

V

C G

or

10V

 

50 mA

10V

 

50 mA

10V

 

50 mA

 

 

 

 

VOL/MUTE

 

VOL/MUTE

 

VOL/MUTE

1

2

3

4

5

1

2

3

4

5

1

2

3

4

5

STANDBYSTANDBYSTANDBY

Figure 9. Regulating Multiple Amplifiers with a Single Volume Controller

NOTE: The 10 V pin of the volume controller connects to the first XPA Half-Rack unit only. There are no jumper wires linking it to subsequent amplifiers.

XTRA Series • Operation

18

Image 24
Contents User Guide Safety Instructions English Specifications Availability FCC Class B NoticePage Contents Page Features Continuous power output for larger roomsAbout this Manual Terms Used in this ManualXtra Series Introduction Application Examples XPA 1002 Application ExampleMounting the XPA 1002 and XPA Tabletop UseUL Guidelines for Rack Mounting Rack Mounting Rack Mounting of the AmplifierFlexible Conduit Adapter Kit Installation Allow Sufficient Spacing for Adequate VentilationUL Requirements Removing the IEC Connector Front Panel Features and Operation Power indicator LED This LED lightsLIMITER/PROTECT Rear Panel Features and Operation Attenuation Inputs RemoteInputsinputs See Remote Volume Control on XPA XPA Do not tin the wires Remote Volume Control Controlling Multiple Amplifiers with One Volume Controller Bridged Mono Output Bridging the Output of the XPATroubleshooting Amplifier Fails to Exit Standby Mode PromptlyAmplifier Enters Standby Mode Too Early Limiter/Protect LED Warning Indicators Over Temp Indicator LEDLED State Problem Description Problem Solution Part Numbers and Accessories Optional AccessoriesIncluded parts Replacement Part number Accessories Part numberUSA, Canada, South America Japan Central America Europe and Africa ChinaAsia Middle East Europe