Henny Penny 590, 592 manual Heating Elements

Page 20

2-20. HEATING ELEMENTS (Continued)

2-20

Model 590/592

Replacement

1.Drain the shortening.

2.Remove the high limit bulb holder from the heating element inside the frypot.

3.Disconnect the heating element wires from the contactors. Label each so it can be replaced in the same position on the new element.

4.Remove the heat contactor, as described in Contactors Section, to access the left side element nuts.

5. Loosen the screws on the element spreaders.

6. Slide element spreaders to the center of the heating element.

7.Using a 7/8” crowsfoot, remove the brass nuts and washers which secure the ends of the elements through the frypot wall.

8. Remove the heating elements from the frypot as a group by lifting the far end, and sliding them up and out towards the rear of the frypot.

Always install new rubber O-rings (2) when installing heating elements.

9.Install new heating elements with new rubber O-rings mounted on terminal ends, and spreaders loosely mounted in the center of the stacked elements.

10. Replace the heating elements, terminal end first at approximately 45º angle, slipping the terminal ends through the front wall of the frypot.

1103

Image 20
Contents Maintenance Maintenance HintsIntroduction PreventiveCheckout High Temperature Limit Control Fuse HoldersReplacement Temperature Probe Replacement Excess force will damage temperature probeEvery 90 days Yearly InspectionGasket UprightReversing the LID Model 590/592 Against to seal the lid Pressure PADPressure pads are plastic strips that the lid cam presses LID Adjustment Solenoid Valve If the core-disc assembly is sticking due to buildup Deadweight Valve Solenoid ValveDeadweight Valve Removal & Cleaning Safety Relief ValveCleaning Steps ValvePressure Gauge Calibration StepsContactors 30 31 34 35If either contactor proves defective, replace as follows Wires Power AmperageHeating Elements Heating Elements 4 mm Gap Drain valve opens when the drain valve handle is pulled Drain ValveExtension Out and drains the shortening out of the potNylatron Strips Replacement Nylatron Strips Replacement