2-4. HIGH TEMPERATURE
LIMIT CONTROL (Continued)
To avoid electrical shock of property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.
Replacement
1.If the tube is broken or cracked, the control will open, shutting off electrical power. The control cannot be reset.
2.Drain shortening from the frypot and discard. A substance in the tube could contaminate the shortening.
3.Remove control panel.
4.Loosen small inside screw nut on capillary tube.
5.Remove capillary bulb from bulb holder inside the frypot.
6.Straighten the capillary tube.
7.Remove larger outside nut that threads into pot wall, and remove defective control from control panel area.
8.Insert new control and replace screws.
9.Uncoil capillary line, starting at capillary tube, and insert through frypot wall.
To avoid electrical shock or other injury, run capillary line under and away from all electrical power wires and terminals. The tube must never be in such a position where it could accidentally touch the electrical power terminals.
10.Carefully bend the capillary tube as shown in photo and place into bulb brackets.