Henny Penny 590, 592 manual Limit Control, Fuse Holders

Page 4

 

 

Model 590/592

2-4. HIGH TEMPERATURE

11. Pull excess capillary line from pot and tighten nut into

LIMIT CONTROL

 

frypot wall.

(Continued)

 

 

 

 

Be sure capillary bulb of high limit is positioned so it does

 

 

not interfere with carrier or get damaged when cleaning

 

 

frypot.

 

12.

With excess capillary line pulled out, tighten smaller nut.

 

13.

Replace inner and front panels.

 

14.

Refill with shortening.

2-5. FUSE HOLDERS

There are two fuse holders on each model of the electric fryers.

 

To check or change fuse, unscrew black fuse holder cap.

To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

Checking Procedure for Fuse Holders

CONTROL PANEL FUSES 3 Phase

Remove the control panel and pull the wires from the fuse holder terminals. Using a multimeter or continuity light, check across the terminals. The circuit should be closed. If not, re- place the fuse (HP# EF02-007) or fuse holder (HP# EF02-006).

2-4

1103

Image 4
Contents Maintenance Maintenance HintsIntroduction PreventiveCheckout High Temperature Limit Control Fuse HoldersReplacement Temperature Probe Replacement Excess force will damage temperature probeEvery 90 days Yearly InspectionReversing the LID UprightGasket Model 590/592 Pressure pads are plastic strips that the lid cam presses Pressure PADAgainst to seal the lid LID Adjustment Solenoid Valve If the core-disc assembly is sticking due to buildup Deadweight Valve Solenoid ValveDeadweight Valve Removal & Cleaning Safety Relief ValveCleaning Steps ValvePressure Gauge Calibration StepsContactors 30 31 34 35If either contactor proves defective, replace as follows Wires Power AmperageHeating Elements Heating Elements 4 mm Gap Drain valve opens when the drain valve handle is pulled Drain ValveExtension Out and drains the shortening out of the potNylatron Strips Replacement Nylatron Strips Replacement