2-7. TEMPERATURE PROBE

REPLACEMENT

Figure 2-1

Figure 2-2

Model 590/592

The temperature probe relays actual shortening temperature to the control. If it becomes disabled, “E06” will show in the dis- play. Also, if temperature is out of calibration more than 10°F, or 10°C, the temperature probe should be replaced. An Ohm check can be performed also. See chart at end of this section.

1.Remove electrical power supplied to the fryer.

To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

2.Drain the shortening from the frypot.

3.Remove the control panel.

4.Using a 1/2” wrench, remove the nut on compression fitting.

5.Remove the temperature probe from the frypot.

6.Place nut and new ferrule on new temperature probe and insert temperature probe into compression fitting until it extends one-half (1/2) inch (1.3 cm) into frypot. Use temp- erature probe gauge provided in temperature probe kit, to ensure proper placement in frypot. See Figures 2-1 & 2-2.

7.Tighten hand tight and then a half turn with wrench.

Excess force will damage temperature probe.

8.Connect new temperature probe to PC board and replace control panel.

9.Replace shortening.

10.Turn power on and check out fryer.

2-6

407

Image 6
Contents Introduction MaintenanceMaintenance Hints PreventiveCheckout High Temperature Limit Control Fuse HoldersReplacement Temperature Probe Replacement Excess force will damage temperature probeEvery 90 days Yearly InspectionUpright Reversing the LIDGasket Model 590/592 Pressure PAD Pressure pads are plastic strips that the lid cam pressesAgainst to seal the lid LID Adjustment Solenoid Valve If the core-disc assembly is sticking due to buildup Deadweight Valve Solenoid ValveDeadweight Valve Removal & Cleaning Safety Relief ValvePressure Gauge Cleaning StepsValve Calibration StepsContactors 30 31 34 35If either contactor proves defective, replace as follows Wires Power AmperageHeating Elements Heating Elements 4 mm Gap Extension Drain valve opens when the drain valve handle is pulledDrain Valve Out and drains the shortening out of the potNylatron Strips Replacement Nylatron Strips Replacement