Model 590/592
To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.
Checkout
1.Remove control panel.
2.Label and remove wires from the switch.
3.OFF
4.Power position. Check from:
5.Pump position. Check from:
#5 to #6 closed circuit #l to #2 closed circuit
#4 to #5 closed circuit #3 to #2 closed circuit
Check across the jumpers on the wires of POWER/PUMP switch. These jumpers have resistors and capacitors which may be faulty.
Replacement
1.With control panel removed, and wires off of the switch, push in on tabs on the switch to remove from the panel.
2.Replace with new switch, and reconnect wires to switch following the wiring diagram.
3.Replace the control panel.
1103 |