Manitowoc Ice QM45 Series service manual Section Before Calling for Service, Checklist

Page 31

Section 5

Before Calling for Service

 

Section 5

 

Before Calling for Service

Checklist

 

If a problem arises during operation of your ice machine, follow the checklist below before calling for service. Routine adjustments and maintenance procedures are not covered by the warranty.

Problem

Possible Cause

Ice machine does not operate.

No electrical power to the ice

 

machine.

 

 

 

ON/OFF/ WASH toggle switch set

 

improperly.

 

Damper in open position (down).

 

 

Ice machine stops, and can be

Safety limit feature stopping the ice

restarted by moving the toggle

machine.

switch to OFF and back to ICE.

 

Ice machine does not release

Ice machine is dirty.

ice or is slow to harvest.

 

 

Ice machine is not level.

 

 

 

Low air temperature around ice

 

machine (air-cooled models).

 

Water regulating valve leaks in harvest

 

mode (water-cooled models).

Ice machine does not cycle

The six-minute freeze time lock-in has

into harvest mode.

not expired yet.

 

Ice thickness probe is dirty.

 

 

 

Ice thickness probe wire is

 

disconnected.

 

Ice thickness probe is out of

 

adjustment.

 

Uneven ice fill (thin at top of

 

evaporator).

Ice quality is poor (soft or not

Poor incoming water quality.

clear).

 

 

 

 

Water filtration is poor.

 

Ice machine is dirty.

 

 

 

Water siphon is not working.

 

 

 

Water softener is working improperly (if

 

applicable).

To Correct

Replace the fuse/reset the breaker/turn on the main switch/plug power cord into receptacle.

Move the toggle switch to the ON position.

Damper must be capable of swinging freely. See page 6-2.

Refer to “Safety Limit Feature” on the next page.

Clean and sanitize the ice machine. See pages 4-3 and 4-4.

Level the ice machine. See page 2-3.

Air temperature must be at least 35°F (1.6°C).

Replace water-regulating valve.

Wait for freeze lock-in to expire.

Clean and sanitize the ice machine. See pages 4-3 and 4-4.

Connect the wire.

Adjust the ice thickness probe. See page 3-5.

See “Shallow or Incomplete Cubes” on the next page.

Contact a qualified service company to test the quality of the incoming water and make appropriate filter recommendations.

Replace the filter.

Clean and sanitize the ice machine. See pages 4-3 and 4-4.

Check the water siphon system. See page 3-4.

Repair the water softener.

Continued on next page...

5-1

Image 31
Contents QM45 Series Ice Machines Installation, Use, CareProcedural Notices Safety NoticesThis manual covers the following model numbers Table of Contents Before Calling for Service MaintenanceChecklist Safety Limit Feature Safety Limits Model Numbers AccessoriesSection General Information Section General InformationModel/Serial Number Location General Information SectionModel/Serial Number Location Commercial Warranty Coverage Owner Warranty Registration CardWHO is Covered by this Limited WARRANTY? Residential Warranty CoverageSection Section Installation InstructionsInstallation Instructions Ice Machine DimensionsLocation of Ice Machine Installation Instructions SectionIce Machine Heat of Rejection Leveling LEGChecking Ice Machine Level Leveling the Ice MachineLeveling Leg and Foot This page Intentionally Left Blank QM-45 ICE Machine FUSE/CIRCUIT Breaker Electrical ServiceFor United Kingdom Only VoltageDrain Connections Water Service/DrainsWater Supply Water Inlet LinesWater Supply and Drain Line SIZING/CONNECTIONS Typical Water Supply Drain InstallationBefore Starting the Ice Machine Installation ChecklistPersonal Injury Potential Ice Machine Operation Section Ice Machine OperationComponent Identification Ice Making Sequence of Operation Ice Machine Operation SectionInitial START-UP or START-UP After Automatic SHUT-OFF QM45 SELF-CONTAINED AIR Cooled Models Water Level Check Operational ChecksSiphon System Siphon System CheckIce Thickness Check ICE Thickness CheckThis page Intentionally Left Blank Cleaning and Sanitizing Procedure Section MaintenanceSection Maintenance Interior Cleaning and SanitizingMaintenance Section Water Distribution Tube Removal DisassemblyWater Distribution Tube Disassembly Remove the Water Distribution TubeRemove the Water Trough InstallationRemove the Ice Damper Remove the Bin Door Model Air-Cooled Condenser Exterior CleaningCleaning the Condenser ICE Machine InspectionSELF-CONTAINED AIR-COOLED ICE Machines Removal from Service WinterizationBefore Calling for Service Section Before Calling for ServiceChecklist Safety Limit Feature Before Calling for Service SectionSafety Limit Notes Safety LimitsSafety Limit Stand-By Mode Determining Which Safety Limit Stopped The Ice MachineSafety Limit #2 Safety Limit #1Page Manitowoc ICE, INC