Section 6 | Electrical System |
|
|
Diagnosing An Ice Machine That Will Not Run
!Warning
High (line) voltage is applied to the control board (terminals #55 and #56) at all times. Removing control board fuse or moving the toggle switch to OFF will not remove the power supplied to the control board.
Step | Check | Notes |
1 | Verify primary voltage supply to ice | Verify that the fuse or circuit breaker is closed. |
| machine. |
|
2 | Verify the | The H.P.C.O. is closed if primary power voltage is present at terminals |
|
| #55 and #56 on the control board. |
3 | Verify control board fuse is OK. | If the bin switch light functions, the fuse is OK. |
4 | Verify the bin switch functions properly. | A defective bin switch can falsely indicate a full bin of ice. |
5 | Verify ICE/OFF/CLEAN toggle switch | A defective toggle switch may keep the ice machine in the OFF mode. |
| functions properly. |
|
6 | Verify low DC voltage is properly | Loose DC wire connections may intermittently stop the ice machine. |
| grounded. |
|
7 | Replace the control board. | Be sure Steps |
|
| not usually related to the control board. |
Part Number |