Refrigeration System | Section 7 |
|
|
Safety Limit #1
Refer to previous page for safety limit operation.
Freeze time exceeds 60 minutes for 6 consecutive freeze cycles.
Possible Cause | Check/Correct |
Improper installation | See “Installation/Visual Inspection Checklist” |
Water system | Low water pressure [20 psi (138 kPa) min.] |
| High water pressure [80 psi (552 kPa) max.] |
| High water temperature (90°F/32.2°C max.) |
| Clogged water distribution tube |
| Dirty/defective water fill valve |
| Dirty/defective water dump valve |
| Defective water pump |
| Loss of water from sump area |
Electrical system | Low incoming voltage |
| Ice thickness probe out of adjustment |
| Harvest cycle not initiated electrically |
| Contactor not energizing |
| Compressor electrically |
Miscellaneous | Restricted condenser airflow |
| High inlet air temperature |
| Remote - 120°F/49°C max.) |
| Condenser discharge air recirculation |
| Dirty condenser filter |
| Dirty condenser |
| Restricted condenser water flow |
| Low water pressure [20 psi (138 kPa) min.] |
| High water temperature (90°F/32.2°C max.) |
| Dirty/defective water regulating valve |
| Water regulating valve out of adjustment |
Refrigeration system | Improper refrigerant charge |
| |
| Defective harvest valve |
| Defective compressor |
| TXV starving or flooding (check bulb mounting) |
| |
| Plugged or restricted high side refrigerant lines or component |
SAFETY LIMIT NOTES
•Because there are many possible external problems, do not limit your diagnosis to only the items listed in this chart.
•A continuous run of 100 harvests automatically erases the safety limit code.
•The control board will store and indicate only one safety limit – the last one exceeded.
•If the toggle switch is moved to the OFF position and then back to the ICE position prior to reaching the
•If a Safety Limit light did not flash prior to the ice machine restarting, then the ice machine did not stop because it exceeded a safety limit.