Section 6 | Electrical System |
|
|
Section 6
Electrical System
Energized Parts Charts
SELF-CONTAINED WATER-COOLED MODELS
|
|
| Control Board Relays |
|
| Contactor |
| ||||
Ice Making | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 7A | 7B | Length | |
Sequence Of |
| Harvest | Harvest |
| Water |
|
|
| Cond. | ||
Water | Air | Dump | Contactor |
| Of Time | ||||||
Operation | Valve | Valve | Inlet | Comp. | Fan | ||||||
Pump | Comp.* | Valve | Coil |
| |||||||
| (Left) | (Right)* | Valve |
| Motor |
| |||||
|
|
|
|
|
|
| |||||
|
|
|
| 35 sec. |
|
|
|
|
|
| |
|
| On | Off |
|
|
|
|
|
| ||
On | On | (when |
| Off | On | Off | Off | Off | 45 Seconds | ||
1. Water Purge |
| ||||||||||
|
| used) | 10 sec. |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |||
|
|
|
| On |
|
|
|
|
|
| |
2. Refrigeration | Off | On | Off | Off | On | Off | On | On | Off | 5 Seconds | |
System | |||||||||||
|
|
|
|
|
|
|
|
|
| ||
FREEZE |
|
|
|
| May |
|
|
|
| Initial | |
|
|
|
| Cycle |
|
|
| May Cycle | is 60 Seconds | ||
SEQUENCE | Off | Off | Off | Off | Off | On | On | ||||
On/Off | On/Off | 30 Seconds | |||||||||
3. |
|
|
|
|
|
|
| ||||
|
|
|
| during |
|
|
|
| thereafter | ||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| the first |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| 45 sec. |
|
|
|
| Until 10 sec. | |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| Cycles |
|
|
| May Cycle | water contact | |
4. Freeze | On | Off | Off | Off | Off | On | On | with ice | |||
Off, then | On/Off | ||||||||||
|
|
|
|
|
|
|
| thickness | |||
|
|
|
|
| On one |
|
|
|
| ||
|
|
|
|
|
|
|
|
| probe | ||
|
|
|
|
| more |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| time |
|
|
|
|
| |
HARVEST |
|
|
|
| 30 sec. |
|
|
|
|
| |
|
|
| On; after | Off, |
|
|
| May Cycle | |||
SEQUENCE | On | On | On | On | On | On | |||||
35 sec. | 15 sec. | On/Off | 45 Seconds | ||||||||
5. Water Purge |
|
|
|
|
|
| |||||
|
|
|
| On |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| ||
6. Harvest | Off | On | On | On | Off | Off | On | On | May Cycle | Bin switch | |
On/Off | activation | ||||||||||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| Until bin | |
7. AUTOMATIC | Off | Off | Off | Off | Off | Off | Off | Off | Off | switch | |
| |||||||||||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| 3 min. delay |
1.Initial
Condenser Fan Motor
The fan motor is wired through a fan cycle pressure control, therefore, it may cycle on and off.
Harvest Water Purge
The circuit board has an adjustable water purge in the harvest cycle. This permits a 0 or 45 second purge cycle.
Auto Shut-Off
The ice machine remains off for 3 minutes before it can automatically restart. The ice machine restarts (steps
Safety Timers
The control board has the following
•The ice machine is locked into the freeze cycle for 6 minutes, before a harvest sequence can be initiated. The freeze lock is bypassed when the toggle switch is moved from the OFF to ICE position on the first cycle only.
•The maximum freeze time is 60 minutes, at which time the control board automatically initiates a harvest sequence (steps
•The maximum harvest time is
Part Number |