USE
Control Panel
The hood can be switched on pushing directly onto the requested speed without firstly having to select 0/1 button.
KEY | LED | FUNCTIONS |
|
L | 0/1 Light | Turns lighting on and off. |
|
T1 | 0/1 Motor on | First speed. | L |
|
| When pressed for about 1 seconds | |
|
|
| |
|
| the motor is switched off. |
|
T2 | Speed | on | Second speed. |
|
| |
T3 | Speed | on | Third speed. |
|
| |
T4 | Speed | Fixed | Max. speed |
|
| |
|
| Flashing | Intensive speed. |
|
| |
|
|
| Suitable for the strongest cooking | |||
|
|
| vapours and odours. The function | |||
|
|
| becomes active when the button is | |||
|
|
| pushed for about 2 seconds. After | |||
|
|
| 10 minutes of functioning it turns | |||
|
|
| off | automatically. | This | function |
|
|
| can be interrupted by means of | |||
|
|
| pressing any of the buttons. | |||
S1 | Led | Fixed | Indicates that the Metal grease fil- | |||
|
|
| ters saturation alarm has been trig- | |||
|
|
| gered, and the filters need to be | |||
|
|
| washed. The alarm is triggered af- | |||
|
|
| ter 100 working hours. (Reset; | |||
|
|
| check the | |||
|
| Flashing | indicates that the activated char- | |||
|
|
| coal odour filter saturation alarm | |||
|
|
| has | been triggered, | and | the filter |
has to be replaced; the metal grease filters must also be washed. The activated charcoal odour filter is triggered after 200 working hours. (Activation and Reset; check the
T1
T2
T3
T4
S1
EN |
| 2 |
| 22 |