Automatic mobile unit recognition (AWK)
^ Set the program place coding. |
^Put the magnetic strip back in the track.
Important:
The magnetic strip must be placed in the track so that the Bit coding, set according to the chart, is visible through the round windows of the track.
^Place the track in the holder of the mobile unit and screw firmly in place.
Bit 6 is not an integral part of the modifiable magnetic strip. Make sure that you code mobile units with side coupling to a track where Bit 6 is set to I.
Mobile units without side coupling must be coded with a track that does not have Bit 6.
The magnetic strips on the G 7825 / G 7826 must have gray magnets. The magnetic strips on the G 7827 / G 7828 must have black magnets.
18