GE ZV800 Install Rear Mounting Screws, Remove protective film on the filters

Page 23

Installation Instructions

UNDER-CABINET INSTALLATION

8 CONNECT ELECTRICAL

WARNING: If house wiring is not 2-wire with a ground wire, a ground must be provided by the installer. When house wiring is aluminum, be sure to use U.L. approved anti-oxidant compound and aluminum-to-copper connectors.

ADVERTISSEMENT :

Si la maison n’est pas câblee avec deux fils et un fil de terre, l’installateur doit installer un fil de terre. Quand les fils sont en aluminium, il faut prendre soin d’utiliser des connecteurs aluminium à cuivre avec une pâte antioxydante approuvée par U.L.

Remove junction box cover and knockout.

Use a conduit connector to secure the conduit to the junction box.

Connect white leads to branch circuit white lead.

Connect black leads to branch circuit black lead.

Connect green/yellow leads to branch circuit green lead or bare ground lead.

Secure all connections with wire nuts on each electrical connector.

Push wires into junction box and replace cover. Be sure wires are not pinched.

Secure electrical panel cover with screws provided.

10INSTALL FILTERS

Remove protective film on the filters.

Filter Locks

NOTE: It is not necessary to install the charcoal filter in a vented installation.

Tip the filter into the slots at the rear of the opening. Lift the filter lock and pull forward until the filter rests in the slots.

Install both metal grease filters.

To remove the filters, press inwards on the handle and pull the filter downwards.

9INSTALL REAR MOUNTING SCREWS

Install 2 Wood Screws

Pull the glass canopy forward to access and install 2 wood screws or fasteners through the bottom of the hood and into the wall.

23

Image 23
Contents Installation Instructions Before YOU Begin Product Dimension and Clearance Installation Options ContentsAdvance Planning Power SupplyDuct Fittings Duct Piece Dimensions Length UsedTools and Materials Required not Supplied Remove the PackagingHood, depends upon ceiling height Wall Mount InstallationsInstallation below a Cabinet Installation below Wall CabinetContains 10 Phillips head screws Check Installation HardwareDuct elbow DUCTWORK, Wiring LocationsInstall Framing for Hood Support Reinstall drywallInstall Duct Bracket Install Mounting BracketMount the Hood Prepare the HoodConnect Electrical Connect DuctworkRemove all packaging materials Install Duct CoversFinalize Installation Tape the template in position along the penciled line WALL-MOUNTED INSTALLATION-RECIRCULATINGJunction box Hood outlets Size and CUT Duct PieceOverlap DeflectorMounting Screw holes Vent holes Charcoal filter Install FiltersCabinet Requirements DUCTWORK, WiringThis hood may be installed beneath a wall-mounted cabinet Install Remove Side Screw Install Side L BracketsCUT the Opening Complete the Installation and Connect Ductwork Remove protective film on the filters Install Rear Mounting ScrewsPub. No