GE 200D9366P004 Performance Data Sheet, Operating Specifications, Special Notices

Page 41

Performance Data Sheet

SmartWater Filtration System

GSWF Cartridge

This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.

The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*

(100% safety factors built in for unmetered usage)

Standard No. 42: Aesthetic Effects

Parameter

USEPA

Influent

Influent Challenge

Effluent

 

% Reduction

Min. Required

 

MCL

Average

Concentration

Average

 

Maximum

Average

Minimum

Reduction

Chlorine

1.845 mg/L

2.0 mg/L+10%

< 0.05 mg/L

 

0.05 mg/L

> 97.29%

96.43%

> 50%

 

 

 

 

 

 

 

 

 

 

T & O

 

Particulate**

143,333 #/mL

at least 10,000 particles/mL

29.83 #/mL

 

140 #/mL

99.98%

99.91%

> 85%

Standard No. 53: Health Effects

Parameter

USEPA

Influent

Influent Challenge

Effluent

% Reduction

Min. Required

 

MCL

Average

Concentration

Average

Maximum

Average

Minimum

Reduction

Turbidity

1 NTU***

10.3 NTU***

1+1 NTU***

0.106 NTU

0.14 NTU

98.97%

98.61%

0.5 NTU

Cysts

99.95% Reduction

200,000 #/L

Minimum 50,000 L

0

0

> 99.99%

> 99.99%

> 99.95%

 

 

 

 

 

 

 

 

 

Lead at pH 6.5

0.015 mg/L

0.15 mg/L

0.15 mg/L+10%

< 0.001 mg/L

< 0.001 mg/L

> 99.33%

> 99.33%

0.010 mg/L

 

 

 

 

 

 

 

 

 

Lead at pH 8.5

0.015 mg/L

0.14 mg/L

0.15 mg/L+10%

0.001 mg/L

0.003 mg/L

> 99.29%

97.86%

0.010 mg/L

Lindane

0.0002 mg/L

0.0216 mg/L

0.002 mg/L+10%

< 0.00002 mg/L

< 0.00002 mg/L

99.07%

98.75%

0.0002 mg/L

 

 

 

 

 

 

 

 

 

Atrazine

0.003 mg/L

0.008 mg/L

0.009 mg/L+10%

< 0.002 mg/L

< 0.002 mg/L

> 76.12%

> 66.67%

0.003 mg/L

 

 

 

 

 

 

 

 

 

*Tested using a flow rate of 0.5 gpm; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C) ** Measurement in Particles/ml. Particles used were 0.5-1 microns

*** NTU=Nephelometric Turbidity units

Operating Specifications

￿Capacity: certified for up to 750 gallons (2,838 l); up to six months

￿Pressure requirement: 40–120 psi (2.8–8.2 bar)

￿Temperature: 33–100ºF (0.6–38ºC)

￿Flow rate: 0.5 gpm (1.9 lpm)

General Installation/Operation/Maintenance Requirements

￿Flush new cartridge at full flow for 3 minutes to purge out trapped air.

￿Replace cartridge when flow becomes too slow.

Special Notices

￿Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.

￿This drinking water system must be maintained according to manufacturer’s instructions, including replacement of filter cartridges.

￿Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.

￿The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.

￿Check for compliance with the state and local laws and regulations.

￿Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Systems must be installed and operated in accordance with manufacturer’s recommended procedures and guidelines.

System tested and certified by NSF International against Standard 42 for the reduction of chlorine, taste and odor, particulate Class I and Standard 53 for the reduction of cyst, lead, Lindane, Atrazine and turbidity.

NSF®

Manufactured for: General Electric Company, Louisville, KY 40225

41

Image 41
Contents Write the model and serial numbers here Model # Serial # Ge.comRefrigerator or Freezer Before You Throw Away Your OldGe.com HOW to Connect ElectricityAbout the controls with temperature settings Installing the Filter Cartridge When to Replace the FilterAbout the water filter. on some models Water Filter CartridgeAbout the shelves and bins Non-Adjustable Shelves on the Door on some modelsRearranging the Shelves To removeFruit and Vegetable Crisper Adjustable Humidity Crisper on some modelsAbout the crispers and pans About the freezer drawer. on some models When replacing the deep full-width basketFreezer Shelves and Baskets Basket RemovalAbout the freezer compartment. on some models Non-Adjustable Shelf on Freezer DoorFreezer Shelf and Basket Fixed Shelf RemovalTo reach the icemaker power switch, pull Icemaker Accessory KitAbout the automatic icemaker. on some models Automatic IcemakerCleaning the Inside Care and cleaning of the refrigeratorCleaning the Outside Preparing to Move Behind the RefrigeratorPreparing for Vacation Freezer Light Replacing the light bulbsRefrigerator Lights Preparation Before YOU BeginTools YOU MAY Need Moving the Refrigerator IndoorsRefrigerator Location Connecting the Refrigerator to the House Water LineClearances Removetop CAP cont. on some modelsTurn on the Water Supply ContPlug in the Refrigerator PUT Therefrigerator in PlaceRemove the Freezerdoorhandle Remove the Fresh Food Door HandleAttach the Freezerdoorhandle Attach the Fresh Food Door HandleLeveling legs have 2 purposes SET the ControlsRemovethedrawerfront RemovethebasketRemovethedrawerfront Remove the Base GrilleAttachand Securethedrawer Front Totheslides Replace the Freezer BasketImportant Notes Reversingthedoorswing Single Door Refrigerator Models onlyTools YOU will Need Removethe Refrigerator DoorRemove Bottom Hinge and Leveling LEG Remove the Freezer DoorTransfer Center Hinge Bracket Transfer Refrigerator Doorhandle Toright RehangfreezerdoorDouble Door Refrigerator Models only Install the Logo BadgeRehangrefrigeratordoor Removetherefrigerator Doors Removing the Doors Double Door Refrigerator Models onlyRemovecenterhinge Removeopposite DoorRehangrefrigeratordoors Install CenterhingeReplaceopposite Door Align Double DoorsWhat YOU will Need Installing the Water Line Icemaker ModelsDrill the Hole for the Valve Shut OFF the Main Water SupplyChoose the Valve Location Connect the Tubing to the Valve Fasten the Shutoff ValveTighten the Pipe Clamp Route the TubingNormal operating sounds Before you call for service…See About the controls Consumer Support Troubleshooting TipsSee Replacing the light bulbs Should be positioned vertically Handle is loose Handle needs adjustingWarranty Registration Department Box Louisville, KY GE Service Protection PlusModel Number Consumer Product Ownership RegistrationOwnership Registration Page What GE Will Not Cover GE Will ReplaceGE and Geprofilemodels One Year Thirty DaysTerms and Conditions What is not CoveredOperating Specifications Performance Data SheetGeneral Installation/Operation/Maintenance Requirements Special NoticesWater Treatment Device

200D9366P004 specifications

The GE 200D9366P004 is a high-performance component designed for various industrial applications, particularly in power generation and distribution systems. This device is a part of General Electric’s extensive lineup of electrical components, renowned for their durability and operational efficiency.

One of the main features of the GE 200D9366P004 is its robust design capacity, built to handle significant electrical loads while maintaining stability and safety. The component is engineered to comply with rigorous industry standards, ensuring not only reliability but also longevity in harsh operational environments. This makes it suitable for a range of applications, from power plants to critical infrastructure systems.

In terms of technologies, the GE 200D9366P004 incorporates advanced electric and electronic control systems that enhance its operational capabilities. This includes state-of-the-art monitoring technologies that provide real-time data on performance metrics, allowing for prompt detection of anomalies and facilitating proactive maintenance strategies. This predictive capability is crucial in minimizing downtime and extending the lifecycle of the equipment.

The operating characteristics of the GE 200D9366P004 are particularly noteworthy. It is designed for optimal thermal performance, ensuring that heat dissipation is managed efficiently. This helps in maintaining consistent performance even under high operational loads. Additionally, the component features advanced insulating materials that contribute to its reliability and efficiency, reducing the risks associated with electrical failures.

Another notable characteristic is its modular design, which simplifies installation and maintenance processes. This modularity allows for easier upgrades and repairs, making it a flexible choice for many organizations looking to enhance their operational efficiency without extensive downtime.

Overall, the GE 200D9366P004 stands out in the industrial landscape for its combination of advanced technology, rugged reliability, and operational efficiency. Whether utilized in power generation, industrial automation, or management of critical electrical infrastructure, this component exemplifies GE’s commitment to quality and innovation in electrical solutions, making it a preferred choice for professionals aiming to achieve high-performance standards in their operations.