Alto-Shaam 100-HW/D643, 400-HW/D4, 400-HW/D6 manual Dimensions Capacity, 100-HW/D4 & 100-HW/D6 HW/D4

Page 9

I N S T A L L A T I O N

DIMENSIONS • CAPACITY

100-HW/D4 & 100-HW/D6 HW/D4

HW/D6

HW/D4

DEPTH

DEPTH

WIDTH & LENGTH

7-1/2" (190mm)

9-1/2" (241mm)

16-1/8" (409mm)

6-3/16" (157mm)

8-3/16" (208mm)

 

 

3/16"-24 (614mm)

-31/8" (79mm) electricalto cord

 

22-3/16" (563mm)

 

 

 

12-1/16" (306mm)

Control

Control

to electrical cord

 

 

4-5/16" (110mm)

 

PRODUCT\PAN CAPACITY (based on 4" deep pans)

D4: 24 lb (10.8 kg) / D443: 32 lbs (14.6 kg) max. max. volume: D4: 15 qt. (19 L) / D443: 21 qt (24 L)

FULL-SIZE PANS*:

One (1) 12" x 20" x 4"

 

GN 1/1 (325mm x 530mm x 102mm)

HALF-SIZE PANS*:

Two (2) 12" x 10" x 4"

 

GN 1/2 (325mm x 265mm x 102mm)

THIRD-SIZE PANS*:

D4: Three (3) / D443: Four (4) 12" x 6' x 4"

 

GN 1/3 (325mm x 176mm x 102mm)

*will also accept 2-1/2" (65mm) deep pans; D6 units will accept 6" (153mm) deep pans

200-HW/D4 & 200-HW/D6

HW/D443

WIDTH & LENGTH

16-1/8" (409mm)

-1/4" (792mm)

 

13-13/16" (350mm)

 

31

 

7" (175mm)

 

 

 

 

 

 

 

One (1) flexible

 

 

 

water-tight tether

1/8"-3 (78mm) electricalto cord

12" (305mm)

36" (914mm)

 

Control

(136mm)

 

 

to electrical cord

Electrical Cord

 

 

60" (1524mm)

 

 

5-3/8"

 

 

5-5/16" (135mm)

 

5" (125mm)

HW/D4 DEPTH

HW/D6 DEPTH

7-1/2" (190mm)

9-1/2" (241mm)

 

6-3/16" (157mm)

8-3/16" (208mm)

 

22-3/16" (563mm)

(614mm)

24-3/16"

 

 

Control

Control

28-15/16" (734mm)

26-9/16" (675mm)

5" (125mm)

7" (175mm)

14-1/2" (367mm)

3-1/16" (78mm)

to electrical cord

to electrical cord

 

One (1) flexible water-tight tether

36" (914mm)

4-5/16" (110mm)

PRODUCT\PAN CAPACITY (based on 4" deep pans)

48 lb (21.6 kg) maximum

max. volume: 30 qt (38 L)

FULL-SIZE PANS*:

Two (2) 12" x 20" x 4"

 

GN 1/1 (325mm x 530mm x 102mm)

HALF-SIZE PANS*:

Four (4) 12" x 10" x 4"

 

GN 1/2 (325mm x 265mm x 102mm)

THIRD-SIZE PANS*:

Six (6) 12" x 6" x 4"

 

GN 1/3 (325mm x 176mm x 102mm)

*will also accept 2-1/2" (65mm) deep pans; D6 units will accept 6" (153mm) deep pans

Electrical Cord 60" (1524mm)

5-5/16" (135mm)

6-3/8" (162mm)

Hot Food Drop-In Well Operation & Care Manual • 7

Image 9
Contents Installation Operating Instructions P a C K I N G L I V E R YSafe operation of electrically and/or gas energized Safety Procedures PrecautionsOptions and Accessories InstallationLeveling Rough CUT Counter TOP OpeningElectrical Connection Refer to wire diagram sent with unit E C T R I C a L SpecificationsRemote Control Housing Mounting Instructions 100-HW/D4 & 100-HW/D6 HW/D4 Dimensions Capacity300-HW/D4, D6, D443, D643 500-HW/D4 & 500-HW/D6 Operating Instructions Reset Thermostats AS NeededDo not ADD Water to HOT Well Place PAN Dividers and Empty Pans in the WellsHalo Heat maintains the maximum amount of product General Holding GuidelinesCleaning Agents Cleaning and Preventive MaintenanceCleaning Materials Protecting Stainless Steel SurfacesClean the Appliance Daily Care and CleaningWarranty Becomes Void if Appliance is Flooded Interior Severe Damage or Electrical Hazard Could ResultN I T a T I O N Service Parts R V I C ETools Required 2mm allen hex wrench Hot Food Drop-In Well Operation & Care Manual Hot Food Drop-In Well Operation & Care Manual Hot Food Drop-In Well Operation & Care Manual Hot Food Drop-In Well Operation & Care Manual Hot Food Drop-In Well Operation & Care Manual Voltage Purchased From Transportation Damage and Claims