S ERVI CE
TH ER MOS TAT ACCURA CY The ele ctronic thermost at is a precise instrume nt and is desi gned to offer trouble free serv ice. If you susp ect the temp eratu re inside the hol din g compartme nt does not match the temp eratur e indicat ed on the digital display, foll ow the inst ruct ions lis ted below.
Che ck to make cert ain the unit voltage
1. mat che s the power source. A power sou rce less tha n tha t requir ed to operate the unit wil l result in inacc urat e tempe ratur es. Verify the temperat ure inside the hol ding
2. comp artme nt with a qual ify thermal indicator.
With the exce ption of the wire shelv es, A. compl etely empty the holding
compa rtment.
Make certain the holding cabinet sens or, B. loc ate d inside the holdin g comp artmen t at the left side of the unit, is complet ely
clean .
Susp end the therma l indicator in the C. cen ter of the holdi ng comp artment.
Allow the temp erature set on the
D. elect ronic thermostat to stabilize for a minimum of one hour befo re comparing the digit al displa y wit h the reading on the thermal indic ator.
DO NOT OPEN THE CAB INE T DOOR( S) DURI NG THE TEMPER ATURE STABILIZATION PERIOD.
If the readin g on the therma l indicator does not matc h the digita l displa y, there may be a proble m with the air sensor. See
trouble shoot ing guide in this manu al; or call the factory service depart men t for advice.
D AN GE R
DISCO NNECT UNI T FROM
POWER SOUR CE BEFORE
CLEANI NG OR SERV ICI NG.
C AU TI ON
THIS SECTION IS PROVIDED FOR THE ASSISTANCE OF QUALIFIED SERVICETECHNICIANS ONLY AND IS NOT INTENDED FOR USE BY UNTRAINED OR UNAUTHORIZED SERVICE PERSONNEL.