Alto-Shaam 1200-S, 1200-UP manual CA UTI on, Serv ICE, Trou BL ES Hootin G Manual Control

Page 21

SERV ICE

TROU BL ES HOOTIN G - MANUAL

CONTROL

 

 

 

 

 

 

 

 

Error

 

 

Possible Cause

Code

Description/Results

Service Required

E-10

Air Sensor Fault (shorted)

Air sensor is shorted.

Air sensor defective?

 

 

Inoperative Unit

 

 

 

Test air sensor by placing sensor in ice water bath 32°F (0°C) and using an ohm-

 

 

 

meter set on the ohm scale. The reading should be 100 ohms resistance. If it is

 

 

 

more than 2 ohms higher or lower, sensor needs to be replaced. If Ohm reading is

 

 

 

100, replace display. If Ohm reading is not 100, replace sensor.

E-11

Air Sensor Fault (open)

Air sensor is open or connection failure.

 

 

Inoperative Unit

Air sensor defective? See above for air sensor test.

E-30

Under temperature

Unit door closed? Door gasket need replacement? Preheat skipped?

 

Oven will not reach set temperature

Unit overloaded or holding frozen product? Defective air sensor or probe? De-

 

fective solid state relay? Bad wire connections or open heating cable?

 

 

 

If none of the above, contact Alto-Shaam Service Department.

E-31

Over temperature

Unit has exceeded its maximum allowable set temperature by 25 degrees for at

least 3 minutes. Unit will shut down.

 

 

Unit will shut down

 

 

 

Defective sensor or poor sensor connection?

 

 

 

Defective relay?

 

 

 

Shorted heater element?

 

 

 

If none of the above, contact Alto-Shaam Service Department.

E-70

Configuration error Inoperative Unit

Contact Alto-Shaam Service Department for correct DIP-switch settings.

or

EEPROM Error - Bad Checksum

Contact Alto-Shaam Service Department for help resetting the control.

E-82

 

 

E-83

 

Inoperative Unit

Stuck button on control panel. Check buttons.

E-90

Button shorted

 

Inoperative Control

If control is still inoperative, contact Alto-Shaam Service Department.

 

 

E-91

Input failure

 

Contact Alto-Shaam Service Department.

 

 

 

-AC-

Power Failure

 

Press any key to acknowedge.

 

 

 

 

 

 

 

 

 

 

 

 

This section is provided for the assistance of qualified techni cians only and is not intende d for use by

 

 

untrained or unauth orized serv ice personn el. If your Alto-Shaam ® unit is not operating properly, check the

 

 

following before calling your Authoriz ed Alto-Shaam®Service Agent:

 

 

Check the power flow to the unit. Plug in outlet? Circuit breaker switch at back of unit turned on?

 

 

 

Do not attempt to repair or serv ice the holding cabinet beyond this point. Contact Alto-Shaam®for the

 

 

 

nearest authorized service agent. Repairs made by any other service agents without prior authorization

 

 

 

by Alto-Shaam®will void the warranty on the unit.

 

 

 

 

 

DANGER

DIS CONNECT UNI T FROM

POWER SOURCE BEFO RE

CLEANI NG OR SERVI CING.

CA UTI ON

THIS SECTION IS PROVIDED FOR THE ASSISTANCE OF QUALIFIED SERVICE TECHNICIANS ONLY AND IS NOT INTENDED FOR USE BY UNTRAINED OR UNAUTHORIZED SERVICE PERSONNEL.

1200 -S, 1200- UP • IN STALLA TI ON /OPERAT ION /SER VICE MANUAL - PG . 20

Image 21
Contents Phone Installation Operation Maintenan CEUnpack I NG Deli VeryDAN GER Safety Proc Edures Preca UTI ONSWA Rning AU TI onDA NG ER CA U TI O NNo TE NST Allatio NWEI GH TS a N D C a PAC IT IES Opti on S an d Acce SSO R IE S NST AllatioCAU TIO N DA NGE RUniversa L PAN Slides SID E Rack S and Shelve SSI TE INS Tallatio Warn INGLevel ING RES Trai NT Requirements -MO BIL E EquipmentAN GER AU TIO NDAN GE R Electr CALUser SA Fety Info Rmation Befo RE Init IAL USEHeatin G Charact Erist ICS OP Eratio N Power Failur EMA NU AL C ONT ROL Operat ION MIN Utes Before L AdingElec TR Onic C Ontr OL O PT ION OP ErationEC TRO NI C C Ontr OL OP ER Atio N ELE Ctron IC Cont ROL SET- UPEL Ectron IC Holdi NG C Abine T Spec IAL F EA TUR ES Heat RecoveryDo UG H Proof ING Stru Ction Hacc P Docume Ntation Optio NTim er Prog ramming Inf ormation Oper ATI O N Elect Ronic CON T ROL OPT I onThermostat contr ol betwe en 60 and 200F 16 to GEN Eral Holding Guid ElinesAution Are ND Clea NingLeaning and PR Eventi VE MAI Ntenance N GE R Clean the Holdin G Cabinet DailyAre a ND Clea Ning Severe DAM AGE or Elect Rical Hazard Could ResultNI Tation Ervi CE AN GE RCA UTI on Serv ICETrou BL ES Hootin G Manual Control TR OUB LE Possi BLE Cause TR Oubl E Shoo Ting EL EC TRO NIC ControlManual Control UP Manual Control Ervi SER VIC E Parts List Exte RiorSER VIC E Parts List Manu AL Contr OL UP with Manual Control 120V Unit Shown 208-240V Unit Shown 1200- S 208 -240V Descrip Tion Servic E Parts LIS T Electr Onic CON TrolErvi Page Page Page Page Page Page Page Page Page 1200- S, 1200 -UP 1200 -S, 1200- UP Page Limited
Related manuals
Manual 51 pages 31 b

1200-S, 1200-UP specifications

Alto-Shaam has long been a frontrunner in the realm of commercial cooking equipment, and their latest offerings, the Alto-Shaam 1200-UP and 1200-S, exemplify their commitment to innovation, quality, and efficiency. Designed for operators across diverse foodservice settings, these units combine precision cooking with versatility to meet the demands of modern kitchens.

The Alto-Shaam 1200-UP features a unique, patented Halo Heat technology. This innovation utilizes a gentle, consistent heat that surrounds food, ensuring even cooking without excessive drying. This technology excels in maintaining food quality and allows for holding foods at optimal serving temperatures without compromising on taste or texture. This makes it ideal for busy restaurants, catering events, and even institutional settings.

On the other hand, the Alto-Shaam 1200-S offers similar cooking capabilities but is tailored for different operational needs. It features a robust design to handle high-volume demands while maintaining reliability and efficiency. Both models are designed with user-friendly controls, enabling chefs to set precise temperatures and times for various cooking applications.

The Alto-Shaam 1200-UP and 1200-S come equipped with digital smart controls that facilitate intuitive operation. Programmable settings allow for easy customization, enabling operators to save time and maximize productivity during peak service periods. The precise temperature control provided by these systems minimizes food waste and ensures consistency, which is crucial in a high-paced culinary environment.

Another significant characteristic of these models is their energy efficiency. Both the 1200-UP and 1200-S utilize advanced insulation technology to retain heat, reducing energy consumption and operational costs. This sustainable design not only benefits the bottom line but also reflects a growing trend towards environmentally responsible cooking practices in the foodservice industry.

Both units offer ample cooking capacity, making them perfect for various food items, whether it be meats, vegetables, or baked goods. Their durable construction ensures longevity, and their sleek design fits seamlessly into any kitchen layout. Additionally, they are equipped with easy-to-clean surfaces, simplifying maintenance and promoting a hygienic work environment.

In summary, the Alto-Shaam 1200-UP and 1200-S stand out with their cutting-edge Halo Heat technology, user-friendly controls, energy efficiency, and versatile cooking options. With these advancements, Alto-Shaam continues to empower foodservice operators to elevate their culinary offerings while optimizing their day-to-day operations.