Lennox Hearth T300P operation manual Installation, Determining Size Of Pipe To Install

Page 12
DETERMINING SIZE OF PIPE TO INSTALL

INSTALLATION

DETERMINING SIZE OF PIPE TO INSTALL

To determine what diameter pipe to use in an installation (3” or 4”), first find the “equivalent pipe length” using the follow- ing guidelines, then plot this figure and the altitude on the chart.

Fill out the installation chart, and calculate your total equivalent pipe length. After you have the total equivalent pipe length, use the Pipe Selection Chart below to determine if your installation requires 3” or 4” exhaust pipe.

INSTALLATION CHART

Type of

# of Elbows

 

Equivalent

Total

Pipe

or Feet of

 

Feet

Equivalent

 

pipe

 

 

 

Feet

 

 

 

 

 

 

90o Elbows

 

x

5

Ft. (1.5M)

 

45o Elbows

 

x

3

Ft. (1M)

 

 

 

 

 

 

 

Horizontal

 

x

1

Ft. (.3M)

 

Pipe

 

 

 

 

 

Vertical Pipe

 

x

.5 Ft.

 

 

 

 

(.15M)

 

A- 90 Degree Elbow

E- 8’ Vertical Pipe

B- 1’ Horizontal Pipe

F- 2’ Horizontal Pipe

C- 45 Degree Elbow

G- 90 Degree Tee

D- Standoff Braces

 

 

 

 

H- Wall Thimble

 

 

 

 

NOTE: All equivalent pipe styles shown to the right are standard for all freestanding models.

SAMPLE INSTALLATION CHART

Type of

 

 

# of El-

 

 

 

Equivalent

 

Total

Pipe

 

 

bows or

 

 

 

Feet

 

 

 

Equiva-

 

 

 

 

 

Feet of

 

 

 

 

 

 

 

lent Feet

 

 

 

 

 

pipe

 

 

 

 

 

 

 

 

90o Elbows /

 

 

2

 

 

 

x

5 Ft. (1.5M)

 

10 (3M)

Tee (A & G)

 

 

 

 

 

 

 

 

 

 

 

 

45o

 

 

 

 

 

1

 

 

 

x

3 Ft. (1M)

 

 

3 (1M)

Elbows (C)

 

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal

 

 

 

3

 

 

 

x

1 Ft. (.3M)

 

3 (1M)

pipe (B & F)

 

 

 

 

 

 

 

 

 

 

 

 

Vertical pipe

 

 

8

 

 

 

x

.5 Ft. (.15M)

 

4 (1.2M)

(E)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total = 20

PIPE SELECTION CHART

 

 

 

 

 

(Feet)

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 “ Diameter Only

 

Length

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pipe

 

 

 

3 or 4”

 

 

 

 

 

 

 

 

10

 

Diameter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Equivalent

0

 

1

2

3

 

4

5

6

7

8

9

10

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Altitude x 1000 Feet

Page 12

Image 12
Contents Freestanding Model T300P Series FREESTANDING PELLET FIRED STOVESRETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT WARNINGS TABLE OF CONTENTS PLANNING YOUR INSTALLATION FLOOR PROTECTION T300P SERIESCLEARANCES INSTALLATION MANUFACTURED MOBILE HOME INSTALLATIONINSTALLING LEG LEVELING BOLTS INSTALLATION CHECK LISTDAMPER ROD INSTALLATION DAMPER ADJUSTMENTPulled Back 3 Notches Fig. ATHERMOSTAT INSTALLATION Terminal Block for ThermostatLeave Jumper on, If Thermostat Is NotUsed Remove Jumper if Thermostat IsTo Be UsedVENTING REQUIREMENTS VENT TERMINATION Chimney Height RequirementsManufactured Mobile Home DETERMINING SIZE OF PIPE TO INSTALL INSTALLING YOUR PELLET STOVE INSTALLATION Installation Configurations / Standard Venting Options This appliance may be connected to an existing flue or by installing listed type “PL” vent pipe. If a liner is run all the way to the top of the existing chimney, the existing flue should be sealed with a steel plate. Start a vertical run with a Tee at the back of the stove. Other options are illustrated below. Note See page 11 for Vent Termi- nation Requirements CARE AND OPERATION CONTROL BOARD OPERATIONStart-upSequence of Events Combustion Voltage Trim Steps Fuel Delivery RateLighting Procedure Without Igniter Manual OperationAutomatic Operation Turning Off Your StoveDAMPER ADJUSTMENT GUIDELINE AUTOMATIC SAFETY FEATURES Power OutageDAMPER OPERATION OverheatingFUEL REQUIREMENTS Pellet Feed / Pellet SizeLong Burn Time CLINKERINGROUTINE MAINTENANCE ROUTINE CLEANINGASH PAN Ash PanPhotoeye Access Inside Hopper Annual Maintenance Procedure Clean Photoeye LensClean Filter Lens Clean-OutTee Remove Filter and Wipe CleanClean-OutTee w/ Cover Removed Remove cover, then remove ashHEAT EXCHANGER TUBES Tube ScraperDOOR ROPE GASKET SPECIFICATIONS - Model T300P Series DEFINITIONS WIRING DIAGRAM TROUBLESHOOTING Qualified Technicians Only PROBLEMSOLUTIONS CAUSES4. Blowers will REPLACEMENT PARTS LIST Auger Misc. PartsREPLACEMENT PARTS DIAGRAMS 14 20 15 OPTIONAL ACCESSORIES Optional AccessoriesCatalog # Model #INSTALLATION TIPS SIMPLE OPERATING INSTRUCTIONS LABEL T300P PELLET STOVE SAFETY LABEL SERVICE AND MAINTENANCE LOG 1110 West Taft Avenue Orange, CA