Combustion Voltage Trim Steps:

1.Push button “twice” for access voltage calibration mode.

2.Identify the current calibration setting indicated by one YELLOW LED bar.

3.Push the “HEAT” control button to adjust setting UP. Each push raises the YELLOW LED bar & increases voltage 5%.

4.Push the “BLOWER” control button to adjust setting DOWN. Each push lowers YELLOW LED bar decreas- ing voltage 5%.

5.Push the calibration button once to lock in selected results.

Fuel Delivery Rate

The feed rate switch manages the fuel delivery rate by controlling the amount of time the auger motor will run as follows:

Feed

Auger Motor

* Lb.’s per

♦ Approxi-

Burn

Rate

ON / OFF

hour fuel

mate

Time

Setting

Time (sec-

delivery

BTU per

(hours)

 

onds)

 

hour

 

 

 

 

fuel de-

 

 

 

 

livery

 

Low =

1 on / 5.00

1.5 Lb.’s /

13,000

34

 

off

hr.

BTU / hr

 

Med.=

1 on / 3.30

2.5 Lb.’s /

21,000

20

 

off

hr.

BTU / hr

 

High =

1 on / 1.60

3.8 Lb.’s /

32,000

14

 

off

hr.

BTU / hr

 

*Feed rates are approximations only. Actual feed rate will vary depending on size, quality and length of fuel used and variations in line voltage.

Estimated heat input based on fuel value of 8400 BTU per lb. of fuel.

Your pellet stove can be operated in either manual or automatic mode. The manual mode is used when op- erating without a thermostat. The automatic mode is used when utilizing a wall thermostat. When utilizing the thermostat capability the burn time can be extended dramatically depending on thermostat setting. Note: It is normal for some ash to build up on the inner glass sur- face at the lower burn settings.

Initial Start-Up / Empty Hopper or Feed Tube: During an initial start-up, or in the case where the hop- per has run out of fuel, it will be necessary to prime the auger feed system. The control board is set to deliver fuel for approximately 2 1/2 minutes during start-up, which, with a fully primed auger tube, will provide the appropriate amount of fuel for ignition.

When first starting your pellet stove, it will be necessary to prime the auger tube. To prime the auger tube you need to first fill the hopper with pellets, and press the ON button on the control board. Wait approximately 2 1/2 minutes and turn the control OFF and then back ON again. Wait an additional 2 1/2 minutes (if necessary) and continue this process until fuel begins to fall into the UltraGrate. Remember, different brand fuels feed at different rates.

Once fuel starts to enter the UltraGrate, turn the stove OFF and then back ON. The auger tube should now be primed and the stove should deliver enough fuel for proper ignition. It may be necessary to follow these pro- cedures in the event that the hopper runs completely out of fuel.

Page 18

Image 18
Contents Freestanding Model T300P Series FREESTANDING PELLET FIRED STOVESRETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT WARNINGS TABLE OF CONTENTS PLANNING YOUR INSTALLATION FLOOR PROTECTION T300P SERIESCLEARANCES INSTALLING LEG LEVELING BOLTS INSTALLATIONMANUFACTURED MOBILE HOME INSTALLATION INSTALLATION CHECK LISTPulled Back 3 Notches DAMPER ROD INSTALLATIONDAMPER ADJUSTMENT Fig. ALeave Jumper on, If Thermostat Is NotUsed THERMOSTAT INSTALLATIONTerminal Block for Thermostat Remove Jumper if Thermostat IsTo Be UsedVENTING REQUIREMENTS VENT TERMINATION Chimney Height RequirementsManufactured Mobile Home DETERMINING SIZE OF PIPE TO INSTALL INSTALLING YOUR PELLET STOVE INSTALLATION Installation Configurations / Standard Venting Options This appliance may be connected to an existing flue or by installing listed type “PL” vent pipe. If a liner is run all the way to the top of the existing chimney, the existing flue should be sealed with a steel plate. Start a vertical run with a Tee at the back of the stove. Other options are illustrated below. Note See page 11 for Vent Termi- nation Requirements CARE AND OPERATION CONTROL BOARD OPERATIONStart-upSequence of Events Combustion Voltage Trim Steps Fuel Delivery RateAutomatic Operation Lighting Procedure Without IgniterManual Operation Turning Off Your StoveDAMPER OPERATION DAMPER ADJUSTMENT GUIDELINEAUTOMATIC SAFETY FEATURES Power Outage OverheatingLong Burn Time FUEL REQUIREMENTSPellet Feed / Pellet Size CLINKERINGASH PAN ROUTINE MAINTENANCEROUTINE CLEANING Ash PanClean Filter Lens Photoeye Access Inside HopperAnnual Maintenance Procedure Clean Photoeye Lens Clean-OutTee Remove Filter and Wipe CleanHEAT EXCHANGER TUBES Clean-OutTee w/ Cover RemovedRemove cover, then remove ash Tube ScraperDOOR ROPE GASKET SPECIFICATIONS - Model T300P Series DEFINITIONS WIRING DIAGRAM SOLUTIONS TROUBLESHOOTING Qualified Technicians OnlyPROBLEM CAUSES4. Blowers will REPLACEMENT PARTS LIST Auger Misc. PartsREPLACEMENT PARTS DIAGRAMS 14 20 15 Catalog # OPTIONAL ACCESSORIESOptional Accessories Model #INSTALLATION TIPS SIMPLE OPERATING INSTRUCTIONS LABEL T300P PELLET STOVE SAFETY LABEL SERVICE AND MAINTENANCE LOG 1110 West Taft Avenue Orange, CA