Lennox Hearth T300P operation manual Routine Maintenance, Door Rope Gasket

Page 25
DOOR ROPE GASKET

ROUTINE MAINTENANCE

DOOR ROPE GASKET

The condition of the rope gasket around the door and windows should be checked periodically and replaced or repaired if necessary. A one-inch strip of paper may be used to perform a test of the integrity of the door seal. Close the door on the paper in several different locations and pull. It is normal to feel only a slight amount of fric- tion. The door gasket does not need to be “tight” in all areas, since a small amount of leakage is not hazardous or detrimental to the performance of your stove.

Door Rope Gasket

(check seal at points indicated)

*(Recommended Frequency of 1 year)

Checking Door Seal

Important Note: Paper should be no longer than a dollar bill.

* (Recommended Frequency of 1 year)

WINDOW WASH

Periodically insert a small piece of cardboard (a busi- ness card) between the window trim and the window. Slide the card back & forth a few times to clear any dust or fibers from the window wash gap. Open the door and repeat from the other side of the glass.

Window Wash

* (Recommended Frequency of 1 year)

REAR STOVE COMPARTMENT

The rear stove compartment should be cleaned periodi- cally (a minimum of once a year). DISCONNECT ELEC- TRICAL CORD PRIOR TO CLEANING STOVE. Any household dust, pet hair or sawdust should be vac- uumed or wiped out of the rear compartment of the stove, room air blower, and Exhaust Blower (paying special attention to vacuuming out the intakes of both blowers). The electrical components should be wiped clean.

MOTOR LUBRICATION

The blowers are permanently lubricated by the manufacturer. Do not apply oil to any part of the blower. Doing so may cause damage.

SMALL AREA PAINT TOUCH-UP (Model T300P only) Using one small piece of 320 grit sand paper and lightly sand the blemish so that the edges are “feathered” or smooth to the touch between the painted and bare sur- faces. Do not let the sand paper gum up with paint, as this will cause scratches on the metal surface. If there are any scratches, use 600 grit sandpaper instead. Mask off surfaces you do not want painted. Paint lightly over the bare surface first as this will act as an undercoat. Then paint over a larger area in smooth even strokes to blend.

Page 25

Image 25
Contents FREESTANDING PELLET FIRED STOVES Freestanding Model T300P SeriesRETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT WARNINGS TABLE OF CONTENTS PLANNING YOUR INSTALLATION T300P SERIES FLOOR PROTECTIONCLEARANCES MANUFACTURED MOBILE HOME INSTALLATION INSTALLATIONINSTALLING LEG LEVELING BOLTS INSTALLATION CHECK LISTDAMPER ADJUSTMENT DAMPER ROD INSTALLATIONPulled Back 3 Notches Fig. ATerminal Block for Thermostat THERMOSTAT INSTALLATIONLeave Jumper on, If Thermostat Is NotUsed Remove Jumper if Thermostat IsTo Be UsedVENTING REQUIREMENTS Chimney Height Requirements VENT TERMINATIONManufactured Mobile Home DETERMINING SIZE OF PIPE TO INSTALL INSTALLING YOUR PELLET STOVE Page Installation Configurations / Standard Venting Options This appliance may be connected to an existing flue or by installing listed type “PL” vent pipe. If a liner is run all the way to the top of the existing chimney, the existing flue should be sealed with a steel plate. Start a vertical run with a Tee at the back of the stove. Other options are illustrated below. Note See page 11 for Vent Termi- nation Requirements CONTROL BOARD OPERATION CARE AND OPERATIONStart-upSequence of Events Fuel Delivery Rate Combustion Voltage Trim StepsManual Operation Lighting Procedure Without IgniterAutomatic Operation Turning Off Your StoveAUTOMATIC SAFETY FEATURES Power Outage DAMPER ADJUSTMENT GUIDELINEDAMPER OPERATION OverheatingPellet Feed / Pellet Size FUEL REQUIREMENTSLong Burn Time CLINKERINGROUTINE CLEANING ROUTINE MAINTENANCEASH PAN Ash PanAnnual Maintenance Procedure Clean Photoeye Lens Photoeye Access Inside HopperClean Filter Lens Clean-OutTee Remove Filter and Wipe CleanRemove cover, then remove ash Clean-OutTee w/ Cover RemovedHEAT EXCHANGER TUBES Tube ScraperDOOR ROPE GASKET SPECIFICATIONS - Model T300P Series DEFINITIONS WIRING DIAGRAM PROBLEM TROUBLESHOOTING Qualified Technicians OnlySOLUTIONS CAUSES4. Blowers will REPLACEMENT PARTS LIST Misc. Parts AugerREPLACEMENT PARTS DIAGRAMS 14 20 15 Optional Accessories OPTIONAL ACCESSORIESCatalog # Model #INSTALLATION TIPS SIMPLE OPERATING INSTRUCTIONS LABEL T300P PELLET STOVE SAFETY LABEL SERVICE AND MAINTENANCE LOG 1110 West Taft Avenue Orange, CA