Lennox Hearth operation manual SPECIFICATIONS - Model T300P Series

Page 26
SPECIFICATIONS - Model T300P Series

SPECIFICATIONS - Model T300P Series

Flue Size

 

3” / 76mm Rear

Width, Overall

 

28 3/4” / 730 mm

Depth, Overall

 

26 1/2” / 660 mm

Height

 

28 3/4” / 730 mm

Floor to Rear

 

 

Flue Center

 

8 3/4” / 222 mm

Facing Back of Unit,

 

 

Outside Edge of Left Leg

 

 

To Center of Rear

 

 

Flue Outlet

 

10 1/2” / 267 mm

Floor to Rear

 

 

Outside Air Inlet

 

10” / 254 mm

Facing Back of Unit

 

 

Outside Edge of Left Leg

 

 

To Center of Air Inlet

 

17 1/2” / 445 mm

Floor Protection

+

Front and Sides:6”/152mm

Requirements

 

Back: Up to 6” / 152mm

Standard Features

 

Fastfire Self Igniter

 

 

Wall Thermostat

 

 

(wire included)

Hopper Capacity

 

50 lbs.

Burn time

14-34 hours

Fuse, Control Board

 

5 amp, 25 volt, 3AG*

Fuse, Igniter

 

6 amp, 125 volt*

Heat Input (Max.)

13,000-32,000 BTU / hr

Overall Efficiency

 

85%

Emissions

0.43 gram / hr (varies w/

 

 

size and type of fuel)

 

 

EPA exempt

Ship Weight

 

363 lbs.

Room Air Blower

 

150 CFM; 1.5 amps,

 

 

2175 rpm

Auger Motor

 

1 RPM; .4 amps

Exhaust Blower

 

95 CFM: 1.0 amps,

 

 

2880 rpm

Note: Dimensions shown are approximations only (+/- ¼”)

BACK VIEW

28 3/4”

8 3/4”

 

10 “

10 1/2”

17 1/2”

SIDE VIEW

26 1/2”

28 3/4”

Face of door opening to stove back

23”

+Non-combustible thermal rated floor protection must be used when installed on carpet (see Floor Protec- tion, page 5). When installed at clearances less than 6”, the floor protector is only required to ex- tend to the wall.

Fuel delivery and burn times will vary depending on size and type of fuel used. Estimated heat in- put based on fuel value of 8400 BTU per lb.

* Fuses are rated as fast blow.

Page 26

Image 26
Contents RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Freestanding Model T300P SeriesFREESTANDING PELLET FIRED STOVES IMPORTANT WARNINGS TABLE OF CONTENTS PLANNING YOUR INSTALLATION FLOOR PROTECTION T300P SERIESCLEARANCES INSTALLING LEG LEVELING BOLTS INSTALLATIONMANUFACTURED MOBILE HOME INSTALLATION INSTALLATION CHECK LISTPulled Back 3 Notches DAMPER ROD INSTALLATIONDAMPER ADJUSTMENT Fig. ALeave Jumper on, If Thermostat Is NotUsed THERMOSTAT INSTALLATIONTerminal Block for Thermostat Remove Jumper if Thermostat IsTo Be UsedVENTING REQUIREMENTS Manufactured Mobile Home VENT TERMINATIONChimney Height Requirements DETERMINING SIZE OF PIPE TO INSTALL INSTALLING YOUR PELLET STOVE INSTALLATION Installation Configurations / Standard Venting Options This appliance may be connected to an existing flue or by installing listed type “PL” vent pipe. If a liner is run all the way to the top of the existing chimney, the existing flue should be sealed with a steel plate. Start a vertical run with a Tee at the back of the stove. Other options are illustrated below. Note See page 11 for Vent Termi- nation Requirements CARE AND OPERATION CONTROL BOARD OPERATIONStart-upSequence of Events Combustion Voltage Trim Steps Fuel Delivery RateAutomatic Operation Lighting Procedure Without IgniterManual Operation Turning Off Your StoveDAMPER OPERATION DAMPER ADJUSTMENT GUIDELINEAUTOMATIC SAFETY FEATURES Power Outage OverheatingLong Burn Time FUEL REQUIREMENTSPellet Feed / Pellet Size CLINKERINGASH PAN ROUTINE MAINTENANCEROUTINE CLEANING Ash PanClean Filter Lens Photoeye Access Inside HopperAnnual Maintenance Procedure Clean Photoeye Lens Clean-OutTee Remove Filter and Wipe CleanHEAT EXCHANGER TUBES Clean-OutTee w/ Cover RemovedRemove cover, then remove ash Tube ScraperDOOR ROPE GASKET SPECIFICATIONS - Model T300P Series DEFINITIONS WIRING DIAGRAM SOLUTIONS TROUBLESHOOTING Qualified Technicians OnlyPROBLEM CAUSES4. Blowers will REPLACEMENT PARTS LIST Auger Misc. PartsREPLACEMENT PARTS DIAGRAMS 14 20 15 Catalog # OPTIONAL ACCESSORIESOptional Accessories Model #INSTALLATION TIPS SIMPLE OPERATING INSTRUCTIONS LABEL T300P PELLET STOVE SAFETY LABEL SERVICE AND MAINTENANCE LOG 1110 West Taft Avenue Orange, CA