Start-up Sequence of Events

CARE AND OPERATION

Note: The control board is equipped with an internal memory which will recall the last setting and mode the stove was in prior to loss of power. Because we individually check each stove prior to packaging, one of the two scenarios will appear when you first plug in your stove.

1). The Green LED at the top of the control board will illu- minate and the blowers will be running. This is a stan- dard cool down mode and will last no longer than five minutes. This happens during testing when the stove is turned off (which initiates cool down mode) and then is unplugged.

2). The Green LED at the top will illuminate and the red and yellow LED’s will illuminate on the control board, indicating that the stove is in the run mode. This hap- pens during testing if the stove is unplugged without first turning the control board off (the control board re- members its last setting, which was the run mode).

If your stove follows that described in number 2 above, simply press the ON / OFF button once to turn the stove off, this will initiate the cool down mode. The stove can be restarted at any time during the cool down mode by press- ing the ON / OFF button once.

Start-up Sequence of Events

1.Fault time delay is initiated (14 minutes 15 seconds).

2.Fuel feed rate of 100% for 1 minute 50 seconds (when trim left at factory setting of 0) auger trim setting ranges from 1:26 to 2:14 depending on -4 to +4 respectively.

3.Exhaust blower operation starts (medium range volt- age).

4.Room air blower operation starts (medium range volt- age).Power LED is activated (steady green).

6.Igniter operation activated (line voltage).

7.Photoeye looks for flame (flame dominance scheme).

8.* If needed second & third fuel dumps are available at predetermined time deliveries (4 minutes & 6 minutes after initial).

Flame Detection Sequence of Events - This is what happens after flame has been detected.

Happens within the Start-up Time Delay sequence. 0 to 1 minute no fuel feed.

Flame settles.

Bed of embers built.

1 minute mark: Fuel Feed rate 20% for 4 minutes 15 seconds (1 second on / 4 seconds off).

2 minute mark: igniter turns OFF / room air blower = panel setting.

5 minute 15 seconds mark: exhaust blower = panel setting / LED indicator still active.

Start-up Time delay ends 14 minutes 15 seconds after pushing the start button!

PHOTOEYE

PN LABEL

LOCATION

POWER

SELECT

MAIN

HARNESS

FUSE

Page 17

Image 17
Contents RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Freestanding Model T300P SeriesFREESTANDING PELLET FIRED STOVES IMPORTANT WARNINGS TABLE OF CONTENTS PLANNING YOUR INSTALLATION T300P SERIES FLOOR PROTECTIONCLEARANCES MANUFACTURED MOBILE HOME INSTALLATION INSTALLATIONINSTALLING LEG LEVELING BOLTS INSTALLATION CHECK LISTDAMPER ADJUSTMENT DAMPER ROD INSTALLATIONPulled Back 3 Notches Fig. ATerminal Block for Thermostat THERMOSTAT INSTALLATIONLeave Jumper on, If Thermostat Is NotUsed Remove Jumper if Thermostat IsTo Be UsedVENTING REQUIREMENTS Manufactured Mobile Home VENT TERMINATIONChimney Height Requirements DETERMINING SIZE OF PIPE TO INSTALL INSTALLING YOUR PELLET STOVE Page Installation Configurations / Standard Venting Options This appliance may be connected to an existing flue or by installing listed type “PL” vent pipe. If a liner is run all the way to the top of the existing chimney, the existing flue should be sealed with a steel plate. Start a vertical run with a Tee at the back of the stove. Other options are illustrated below. Note See page 11 for Vent Termi- nation Requirements CONTROL BOARD OPERATION CARE AND OPERATIONStart-upSequence of Events Fuel Delivery Rate Combustion Voltage Trim StepsManual Operation Lighting Procedure Without IgniterAutomatic Operation Turning Off Your StoveAUTOMATIC SAFETY FEATURES Power Outage DAMPER ADJUSTMENT GUIDELINEDAMPER OPERATION OverheatingPellet Feed / Pellet Size FUEL REQUIREMENTSLong Burn Time CLINKERINGROUTINE CLEANING ROUTINE MAINTENANCEASH PAN Ash PanAnnual Maintenance Procedure Clean Photoeye Lens Photoeye Access Inside HopperClean Filter Lens Clean-OutTee Remove Filter and Wipe CleanRemove cover, then remove ash Clean-OutTee w/ Cover RemovedHEAT EXCHANGER TUBES Tube ScraperDOOR ROPE GASKET SPECIFICATIONS - Model T300P Series DEFINITIONS WIRING DIAGRAM PROBLEM TROUBLESHOOTING Qualified Technicians OnlySOLUTIONS CAUSES4. Blowers will REPLACEMENT PARTS LIST Misc. Parts AugerREPLACEMENT PARTS DIAGRAMS 14 20 15 Optional Accessories OPTIONAL ACCESSORIESCatalog # Model #INSTALLATION TIPS SIMPLE OPERATING INSTRUCTIONS LABEL T300P PELLET STOVE SAFETY LABEL SERVICE AND MAINTENANCE LOG 1110 West Taft Avenue Orange, CA