ROUTINE MAINTENANCE
*Inspect your stove or insert at minimum frequency stated until you establish a minimum frequency required for your installation (frequency will vary depending upon fuel BTU value / ash content, usage, and misc. installation variables).
ROUTINE CLEANING | ASH PAN | |
Note: Stove will need to be shut off and cooled enough to | The ash pan will have to be emptied periodically, de- | |
handle before routine cleaning is performed. | pending on amount of fuel consumed. The T300P Series | |
Always disconnect power before doing any routine clean- | ash pan is pulled straight out using the black pull knob | |
ing. |
| located on the front of the ash pan (see following pic- |
The following areas need to be inspected and cleaned | ture). | |
| ||
during routine cleaning: | Ash Pan | |
|
| |
• UltraGrate (burn grate) |
| |
• | Ash Slide Plate |
|
• | Ash Pan |
|
• | Heat Exchange Tubes |
|
• | Photoeye |
|
• Exhaust Passages and Vent Pipe |
| |
• | Gaskets |
|
• | Window Wash |
|
• | Rear Stove Compartment |
|
UltraGrate (BURN GRATE) |
| |
The UltraGrate should be inspected periodically to as- |
| |
sure that the air holes have not become clogged with ash |
| |
or clinkers. The UltraGrate can easily be cleaned with |
| |
the grate scraper / ash pan tool, or it can be removed for |
| |
cleaning. It is very important to monitor the ash build up |
| |
under the UltraGrate, as excessive amounts of ash will |
| |
block combustion air from entering the grate, causing | * (Recommended Frequency of 2 days – 2 weeks) | |
pellets to | ||
grate is easily dumped into the ash pan by pulling out the | ASH SLIDE PLATE | |
ash slide weekly as shown below. The grate cleaning | ||
procedure is the same for all models. | Ash that accumulates around the grate can be “dropped” | |
|
| into the ash pan without opening the firebox door. Simply |
| UltraGrate | pull open the ash release slide plate as shown in photo |
|
| using the grate scraper tool provided. Remove the ash |
pan as shown. Note: Make sure to fully close the plates when finished. Failure to close the ash release slide plates completely may cause the fuel to burn poorly (due to reduced airflow through the grate), which may then cause pellets to “pile up” in the grate.
Ash Slide Plate
* (Recommended Frequency of 1 day – 2 weeks)
*(Recommended Frequency of 1 day – 2 weeks.)
Page 22