2-1

REFRIGERATION / ELECTRICAL

REFRIGERANT

The correct type of refrigerant will be stamped on each serial plate. The case refrigeration piping is factory sealed, pressurized and leak tested. Before making refrigeration hookups, depress universal line valve to ensure that coils have maintained pressure during shipment.

!WARNING

Refrigerant vapor is hazardous to your health and can cause death.

Avoid breathing refrigerant and lubrication vapor or mist. Exposure may irritate eyes, nose and throat. If accidental system dis- charge occurs,ventilate work area before resuming service.

Always wear safety goggles and protective gloves when working with refrigerants. Contact with refrigerant may cause injury. Disconnect hoses with extreme caution! All hoses may contain liquid refrigerant under pressure.

Be sure that any room where you are working is thoroughly ventilated, especially if a leak is suspected.

Read all safety information regarding the safe handling of refrigerant and refrigerant oil, including the Material Safety Data Sheet. MSDS sheets can be obtained from your refrigerant supplier.

Refrigeration lines are under pressure and should be depressurized before attempting to make any connections.

When brazing pipes, be sure to use the insulation blanket shipped with the merchandiser to prevent fire or damage to the plastic case bottom.

REFRIGERANT PIPING

Connection Location

The refrigerant line connections are at the right- hand end of the merchandiser (as viewed from the front) beneath the display pans. A sticker marks the location of the connection “pod.” The installer must saw a hole through the pod to exit the case.

After connections have been made, seal this outlet thoroughly. Seal both the inside and the outside. We recommend using an expanding polyurethane foam insulation.

Multiplexing

Piping of cases operating on the same refrigera- tion system may be run from case to case. DO

NOT RUN REFRIGERANT LINES THROUGH CASES

THAT ARE NOT ON THE SAME REFRIGERATION

SYSTEM BRANCH as this may result in poor refrigeration control and compressor failure.

Interconnecting piping inside the merchandiser must be located as shown below to allow room for lifting the hinged fan plenums and for clear- ance beneath the display pans. The intercon- necting piping may be run outside the case.

Display Pan

Fan Coil

Piping Location

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

Service Merchandisers

Image 19
Contents Service Merchandisers Page Contents Ansi Z535.5 Definitions ServiceWarranty Revision History Revision BService Merchandisers SafetyIf in doubt, do not Enter and inform the client NSF Certification InstallationLocation Shipping Braces Merchandisers Shipped With END InstalledShipping Damage Exterior LoadingPreparation Case LevelingRaise Lower Leveler AdjustmentGlass Positioning Optional Flexible Wiper Gasket Adjustment Bolt0420057B Joining Instructions Installing Coil Cover and Drip TrayInstalling Optional Wrap Board Drip Tray Connector Drip TubeReplace wireway cover Restore power Installing Optional Scale Stand 12INSTALLATION Connection Location Refrigeration / ElectricalRefrigerant Refrigerant PipingLiquid Line Control SettingsInsulation Suction LineDefrost Termination Thermostat Refrigeration ThermostatElectrical Connections Field WiringIdentification of Wiring Merchandiser Electrical DataDrip Piping and Splashguards Installing Drip PipingWaste Outlet and Water Seal To Install Lower Front Panel Installing Splashguard and Lower Front PanelDetail Installing Bottom Rear Panel Load Limits Start UP / OperationStart UP StockingSmbt This is an NSF-7 Do not Destroy Do Not Use 41F 0420057B 4MAINTENANCE Clean and sanitize according to Health Code requirements Cleaning ANTI-REFLECTIVE Glass Disconnect fan from wiring harness ServiceReplacing FAN Motors and Blades Canopy Fixture Removing Polycarbonate Lamp CoversRail Fixture Replacing Fluorescent Lamps Electrical Service ReceptaclesReplacing Lamp Holders and END Caps Lamp Ballast Replacing Electronic BallastCylinder Removal Tool Replacing Cylinders Single Pane GlassSet Screw Locations Hinge Hardware Replacing Glass Hand GripTechnique Repairing Aluminum Coil

P/N 0420057_B specifications

The Hussman P/N 0420057_B represents a cutting-edge refrigeration solution designed for modern retail environments, particularly those requiring efficient display systems for perishable goods. As part of Hussman's extensive product lineup, this unit integrates advanced technologies tailored to enhance both performance and energy efficiency.

One of the standout features of the 0420057_B is its state-of-the-art refrigeration system, which employs a combination of environmentally friendly refrigerants and high-efficiency compressors. This design not only supports compliance with stringent environmental regulations but also contributes to reduced energy consumption, ultimately leading to lower operational costs for retailers. The unit is built to maintain consistent temperatures, ensuring that products are stored and displayed at optimal conditions, thus prolonging freshness and quality.

Another key characteristic of the Hussman P/N 0420057_B is its user-friendly interface. Retail staff can easily monitor and adjust temperature settings, ensuring that the display conditions meet specific product requirements. This feature enhances operational efficiency and minimizes the risk of temperature-related spoilage. Additionally, digital temperature controls come equipped with alarms that alert staff to any fluctuations, acting as a safeguard for perishable inventory.

The design of the unit emphasizes practicality and aesthetics. With a sleek, modern appearance, the 0420057_B fits seamlessly into various store layouts while maximizing product visibility. The glass door design allows for enhanced product presentation, attracting customers and facilitating easy access for quick purchasing decisions.

Durability is a crucial characteristic of Hussman products, and the 0420057_B is no exception. Constructed from high-quality materials, this refrigeration unit is designed to withstand the rigors of daily retail operations. The robust build ensures longevity, reducing maintenance frequency and operational downtimes, which are critical aspects for retailers aiming to enhance their profit margins.

Moreover, the Hussman P/N 0420057_B incorporates intelligent technology, such as smart sensors that optimize energy use based on real-time conditions. This capability not only enhances energy efficiency but also supports retailers in meeting sustainability goals, making this unit a valuable addition to any eco-conscious business strategy.

In conclusion, the Hussman P/N 0420057_B is a versatile refrigeration solution that combines advanced technology, user-friendly features, and sleek design to meet the demanding needs of modern retail environments. Its focus on energy efficiency, durability, and optimal product preservation makes it an essential investment for retailers looking to enhance their operational effectiveness while ensuring customer satisfaction.