Unified Brands VENTILATION SYSTEMS specifications Ventilation Systems, Operators Manual

Page 1
OPERATORS MANUAL

OPERATORS MANUAL

This manual provides

Installation & Operating instructions for

VENTILATION

SYSTEMS

NOTIFY CARRIER OF DAMAGE AT ONCE.

It is the responsibility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage, including concealed damage. Avtec suggests that if you are suspicious of damage to make a notation on the delivery re- ceipt. It will be the responsibility of the consignee to file a claim with the carrier. We recommend that you do so at once.

Manufacture Service/Questions 888-994-7636.

Information contained in this document is known to be current and accurate at the time of printing/creation. Unified Brands recommends referencing our product line websites, unifiedbrands.net, for the most updated product information and specifications.

1055 Mendell Davis Drive

Jackson, MS 39272

888-994-7636, fax 888-864-7636

avtecind.com

P/N OMANUAL_VMR-09/06
Image 1
Contents OPERATORS MANUAL VENTILATION SYSTEMS1055 Mendell Davis Drive Jackson, MS 888-994-7636,fax avtecind.comTABLE OF CONTENTS Air Adjustment Baffle VENTILATOR FEATURES AND ACCESSORIESPERIODIC MAINTENANCE G. Fusible Link Replacement1I. TYPES OF SYSTEMS Installation shall be in accordance with NFPA NOTE Welds must not impede operation of damper Page Page Fig 8a Fig 8b 9.Terminal Block #11 TB-11has three 3 pairs of terminals. The first pair of terminals are low voltage connections for the detergent low level probe. The probe should be installed in the detergent container so that it does not protrude above the top of the detergent pump inlet strainer. fig. #9 This is intended to prevent cavitation of the pump and will advise when the tank needs to be refilled. The probe rods may be cut to facilitate a neat and effective installation For authorized sevice techinician use only Terminal Block DesignationError! Not a valid link Page VI. OPERATION vac as long as the START Button is depressed a. Fan Start b. Setting the PAWS d. Reviewing The Daily Event Schedule OFF/WASH Page l. Detergent Pump and Tank Refer to fig E. Fire Dampers 1. Fusible Link Type fig. 3. Slot-TypeInternal Air Make-Up D. Grease Collection Receptacle B. VCW PANEL - ELECTRICAL A. PAWS PANEL - ELECTRICALC. PAWS/VCW PANEL - PLUMBING ITEM NOE. ELECTRO - MECHANICAL DAMPER D. EVAC DETERGENTITEM NO DESCRIPTIONG. HOOD CANOPY F. FUSIBLE LINK DAMPERITEM NO AVTEC PART NOCleaner/Degreaser Cleaner/DegreaserFor Exhaust Ventilator Auto-washCleaner UNIQUE, POWERFUL CLEANING FORMULAProject Name AIR MOVEMENT RECORDINGSA. ENERGY AIRE HOODS - EXHAUST B. FILTER HOODS - EXHAUSTPage EXHAUST CALCULATING AND RECORDING AIR MOVEMENTSUPPLY FOR THE NAME AND LOCATION OF THE NEAREST AVTEC SERVICE AGENCY, CALL OR WRITE TO