Unified Brands VENTILATION SYSTEMS D. Evac Detergent, E. Electro - Mechanical Damper, Item No

Page 27

16

PB VLV0313

1-1/2" Supervised Shut-Off Valve [Water]

17

PB VLV0302

1/2" Check Valve, Br.

18

PB VLV0303

3/4" Check Valve, Br.

19

PB VLV0304

1" Check Valve, Br.

20

PB VLV0332

3/8" Check Valve, Br.

21

600-1104

1/4" Check Valve, Br.

22

PB VLV0305

1-1/4" Check Valve, Br.

23

PB VLV0316

1-1/2" Check Valve, Br.

24

HD STN0303

1/2" Wye [Line] Strainer, B.I.

25

PB WYE0301

3/4" Wye [Line] Strainer, B.I.

26

PB STN0306

1" Wye [Line] Strainer, B.I.

27

PB WYE0302

1-1/4" Wye [Line] Strainer, B.I.

28

HD STN0305

1-1/2" Wye [Line] Strainer, B.I.

29

PB SUP0301

1/2" Shock Arrestor

30

HD GGE0303

1/2" Press/Temp. Gauge

31

PB BRK0301

1/2" Vacuum Breaker, Br.

32

PB BRK0305

3/4" Vacuum Breaker, Br.

33

PB BRK0302

1" Vacuum Breaker, Br.

34

PB BRK0306

1-1/4" Vacuum Breaker, Br.

35

PB BRK0312

1-1/2" Vacuum Breaker, Br.

36

PB VLV0317

3/4" Pressure Reducing Valve

37

PB VLV0326

1" Pressure Reducing Valve

38

PB VLV0403

1-1/4" Pressure Reducing Valve

39

HD PMP0301

Single Head Diaphragm Pump [Detergent]

40

HD PMP0303

Foot Valve

41

PB VLV0342

Check Anti-Syphon Valve

 

 

 

D. EVAC DETERGENT

ITEM NO.

PART NO.

DESCRIPTION

1

FL DET0302

EVAC 1 Gallon

2

FL DET0303

EVAC 5 Gallon

E. ELECTRO - MECHANICAL DAMPER

ITEM NO.

AVTEC PART NO.

DESCRIPTION

1

FA SCW0301

1-1/2" S/S Spring

2

HD SPR0303

Damper Spring [Right]

3

HD SPR0304

Damper Spring [Left]

4

HD SPR0306

Solenoid Return Spring

5

HD KNB0301

Red Knob [Damper]

6

EL CNT0323

Terminal Section

7

EL CNT0348

Terminal Section End Stop

8

EL RLY0311

Fire Relay [Damper]

9

HD SOL0313

Damper Solenoid

10

EL SWT 0323

300ο F, Normally Open Thermoswitch

11

411-0226

Electro-Mechanical Damper Instruction [Label]

12

HD BOT0301

Convolution Boot

13

AS ASY0301

AW Damper Linkage Assembly Complete

14

AS LNK0302

350ο F, Fusible Link

15

AS CBL0301

Stainless Steel Cable

16

AS SLV0301

Crimp Sleeve (For S.S. Cable)

24

Image 27
Contents 888-994-7636,fax avtecind.com VENTILATION SYSTEMSOPERATORS MANUAL 1055 Mendell Davis Drive Jackson, MSTABLE OF CONTENTS G. Fusible Link Replacement VENTILATOR FEATURES AND ACCESSORIESAir Adjustment Baffle PERIODIC MAINTENANCE1I. TYPES OF SYSTEMS Installation shall be in accordance with NFPA NOTE Welds must not impede operation of damper Page Page Fig 8a Fig 8b 9.Terminal Block #11 TB-11has three 3 pairs of terminals. The first pair of terminals are low voltage connections for the detergent low level probe. The probe should be installed in the detergent container so that it does not protrude above the top of the detergent pump inlet strainer. fig. #9 This is intended to prevent cavitation of the pump and will advise when the tank needs to be refilled. The probe rods may be cut to facilitate a neat and effective installation For authorized sevice techinician use only Terminal Block DesignationError! Not a valid link Page VI. OPERATION vac as long as the START Button is depressed a. Fan Start b. Setting the PAWS d. Reviewing The Daily Event Schedule OFF/WASH Page l. Detergent Pump and Tank Refer to fig E. Fire Dampers 1. Fusible Link Type fig. 3. Slot-TypeInternal Air Make-Up D. Grease Collection Receptacle ITEM NO A. PAWS PANEL - ELECTRICALB. VCW PANEL - ELECTRICAL C. PAWS/VCW PANEL - PLUMBINGDESCRIPTION D. EVAC DETERGENTE. ELECTRO - MECHANICAL DAMPER ITEM NOAVTEC PART NO F. FUSIBLE LINK DAMPERG. HOOD CANOPY ITEM NOUNIQUE, POWERFUL CLEANING FORMULA Cleaner/DegreaserCleaner/Degreaser For Exhaust Ventilator Auto-washCleanerB. FILTER HOODS - EXHAUST AIR MOVEMENT RECORDINGSProject Name A. ENERGY AIRE HOODS - EXHAUSTPage CALCULATING AND RECORDING AIR MOVEMENT EXHAUSTSUPPLY FOR THE NAME AND LOCATION OF THE NEAREST AVTEC SERVICE AGENCY, CALL OR WRITE TO