User’s Manual
Problem | Possible Cause | Remedy |
The unit is not |
| For model 29AD only: |
cold enough |
| is the defrost timer set |
(continued) |
| to the correct time of day? |
|
| See INITIAL |
The unit is not cold | The door was left open | Turn off the unit to manually |
enough (Frost free | causing the evaporator | defrost the evaporator. |
units only) | behind the back wall to | See DEFROSTING. |
| fill with frost preventing |
|
| proper air flow and cooling. |
|
The unit frosts | Unit is manual | Models |
up | defrost model | and Combo 29A and |
|
| 75A are manual defrost. |
|
| Refer to DEFROSTING |
| Door gasket not | Adjust door. See |
| sealing properly | ALIGNING THE DOOR |
| High ambient | Defrost unit manually. |
| temperatures or | See DEFROSTING |
| humidity |
|
Water is leaking | Water supply | Tighten fitting. See |
out the back | connection leaking | CONNECTING THE |
of the unit |
| WATER SUPPLY |
Ice cubes | Door gasket not | Adjust door. See |
sticking together | sealing properly | ALIGNING THE DOOR |
| Infrequent use of cubes | Break apart cubes |
Noise during | Copper water supply | Carefully bend tubing |
operation | tubing contacting | away from cabinet and |
| internal components | components |
| Fan blade touching | Remove obstruction |
| obstruction (wiring, |
|
| foam insulation, etc.) |
|
No ice | Bin arm locked in | Lower bin arm |
| upright position |
|
Not enough ice | Control set too cold | Adjust control to a |
|
| warmer setting |
|
| |
| Ice cube size too | Set cube size smaller. |
| large | See ADJUSTING ICE |
|
| CUBE SIZE |
Water leaks into | Water level set too | Set cube size smaller. |
ice bucket | high | See ADJUSTING ICE |
|
| CUBE SIZE |
Fresh food section | Ice bucket not fully | Push ice bucket |
on Combo units | inserted | into place |
too cold |
|
|
| Temperature control | Set control to warmer |
| set too cold | setting (COUNTER- |
|
| CLOCKWISE) |
28