Instructions for the installer
6.2 Regulation for LPG
Loosen screw A and push support B all the way. Use a double head wrench to remove nozzle C and assemble the suitable one, following the instructions indicated in the reference charts, with respect to the type of gas to use. The screwing torque of the nozzle should never exceed 3 Nm. Reposition support B so that nozzle C is covered perfectly.
Place the burner on its support and ignite it. Move the Venturi tube D to regulate the air flow until the flame is stable and burns regularly, then secure the tube by means of screw A.
|
|
| LPG – 2.75 kPa |
|
|
| ||
| Burner |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| Nominal gas |
|
| Injector |
|
| |
|
|
| consumption |
|
| (mm) |
|
|
|
|
| (MJ/h) |
|
|
|
|
|
|
|
|
|
|
|
| ||
| Auxiliary (1) |
| 4.8 |
|
| 0.60 |
|
|
|
|
|
|
|
|
| ||
| Semi rapid (2) |
| 6.0 |
|
| 0.68 |
|
|
|
|
|
|
|
|
| ||
| Rapid (3) |
| 9.5 |
|
| 0.85 |
|
|
|
|
|
|
|
|
| ||
| Rapid (4) |
| 12.5 |
|
| 0.95 |
|
|
|
|
|
|
|
|
| ||
| Wok (5) |
| 15.0 |
|
| 1.05 |
|
|
16