Instructions for the installer
6.3 Regulation for natural gas
The hob has been adjusted for natural gas at a pressure of 1.0kPa.
To allow the unit to work back with this type of gas, after it has been adjusted for LPG, perform the same operations described in paragraph “6.2 Regulation for LPG”, but refer to the following table for the proper injectors.
|
|
| NG – 1.0 kPa |
|
|
| ||
| Burner |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| Nominal gas |
|
| Injector |
|
| |
|
|
| consumption |
|
| (mm) |
|
|
|
|
| (MJ/h) |
|
|
|
|
|
|
|
|
|
|
|
| ||
| Auxiliary (1) |
| 4.8 |
|
| 0.98 |
|
|
|
|
|
|
|
|
| ||
| Semi rapid (2) |
| 6.0 |
|
| 1.10 |
|
|
|
|
|
|
|
|
| ||
| Rapid (3) |
| 11.5 |
|
| 1.50 |
|
|
|
|
|
|
|
|
| ||
| Rapid (4) |
| 12.2 |
|
| 1.55 |
|
|
|
|
|
|
|
|
| ||
| Wok (5) |
| 15.0 |
|
| 1.70 |
|
|
7. FINAL OPERATIONS
Having carried out the above adjustments, reassemble the appliance following, backwards, the instructions in paragraph “6.1 Removing the hob”.
7.1Regulation of minimum for natural gas
Replace the components on the burner and slide the knobs on the gas tap pins.
Light the burner and set it at minimum position. Remove the knob and turn the regulation screw inside or next to the gas tap pin (depending on the model) until you get a suitable minimum flame.
Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out).
7.2Regulation of minimum for LPG
To regulate the minimum for LPG, completely tighten (clockwise) the screw inside or next to the gas tap pin (depending on the model).
The diameters of the
After having regulated the device with gas other than the one tested, replace the label located on the guard with the one that corresponds to the new gas. The label is inside the bag that contains the nozzles provided.
17