Sapphire Audio DV425TR owner manual Horizontal Installation Vent Graph

Models: DV425TR

1 60
Download 60 pages 11.22 Kb
Page 27
Image 27
HORIZONTAL INSTALLATION VENT GRAPH

DV425TR DIRECT VENT ROOM HEATER

HORIZONTAL INSTALLATION VENT GRAPH

1.Measure the distance from the top of stove to the center of the 90° elbow. On the graph below, draw a horizontal line from that measurement on the vertical axis across until it intersects with the slanted line.

2.From the point of this intersection, draw a vertical line to the bottom of the graph.

3.The point at which this line meets the bottom line of the graph is the maximum length of the horizontal run.

Example 1: If the vertical dimension from the top of the stove to the center of the 90° elbow is 7’ (2.13m), the horizontal run to the outer wall flange must not exceed 9’ 9” (2.97m).

Example 2: If the vertical dimension from the top of the stove is 21’ (6.4m), the horizontal run to the outer wall flange must not exceed 7’ 3” (2.21m).

4.Each 90° elbow is equivalent to 3' of vent pipe and each 45° elbow is equivalent to 1' of vent pipe, and must subtracted from vent

pipe run. A single vertical to horizontal 90° elbow is already calculated into the allowable 15' run. Each additional 90° elbow reduces the maximum horizontal distance by 3'.

Example:

The use of [3] elbows would reduce the allowable horizontal run to 9' (3 - 1 = 2 elbows x 3' = 6'; 15' max. - 6' = 9' max.)

Notes:

The maximum horizontal vent run is 15’ (4.57m) when the vertical vent rise is 10’ (3.05m).

The minimum horizontal vent run is 12” (305mm).

Minimum wall thickness is 4” (102mm). Maximum wall thickness is 20” (508mm).

Horizontal sections require a 1/4” (6mm) rise for every 12” (305mm) of horizontal travel.

Exterior Vent Diameter = 6 5/8” (177mm); Inner Vent Diameter = 4” (101mm)

Horizontal sections require noncombustible support every 3’ (914mm) , e.g. plumbing tape.

EXCEPTION FOR REAR VENT KIT (Part #844-8920), HORIZONTAL INSTALLATION: The maximum horizontal vent run is 2' (61cm)

The maximum horizontal vent run with a 45° elbow is 14" (35cm)

No external minimum rise is required. The minimum horizontal vent run is 11-5/8" (29cm).

For any vertical rise when rear venting, a minimum of 2' (61cm) vertical must be used prior to any horizontal run.

Rear Venting w/ Vertical Rise

 

 

 

TOP VENT GRAPH

 

 

 

30'

 

 

 

 

 

30'

 

 

 

 

28'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28'

 

 

 

 

 

 

 

26'

 

 

 

 

 

26'

 

 

 

 

 

 

 

24'

 

 

 

 

 

24'

 

 

 

 

 

 

 

22'

 

 

 

 

EX. 2

22'

 

 

 

 

 

 

 

20'

 

 

 

 

VERTICAL

20'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18'

 

 

 

 

DISTANCE

 

 

 

 

 

 

 

 

 

 

 

18'

 

 

 

 

 

 

 

 

 

 

 

FROM

 

 

 

 

 

 

 

16'

 

 

 

 

APPLIANCE

16'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14'

 

 

 

 

TO 90° ELBOW

14'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12'

 

 

 

 

 

12'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10'

 

 

 

 

 

10'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8'

 

 

 

 

EX. 1

8'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6'

 

 

 

 

 

6'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4'

 

 

 

 

 

 

 

4'

 

 

 

 

 

2'

 

 

 

 

 

 

 

2'

 

 

 

 

 

0'

2'

4'

6'

8'

10'

12'

14'

0'

4'

6'

8'

10'

 

11"

2'

 

(MIN)

 

 

 

 

 

 

(MAX)

(MIN)

 

 

 

(MAX)

TOTAL HORIZONTAL RUN TO OUTSIDE OF EXTERIOR WALL (EXCLUDING ELBOWS)

NOTE: If your installation falls within the grey- shaded area on graph, see information on VERTICAL DAMPER ADJUSTMENT ON pg. 48.

02/01

Page 27

250-5533

Page 27
Image 27
Sapphire Audio DV425TR owner manual Horizontal Installation Vent Graph