| DV425TR DIRECT VENT ROOM HEATER | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TROUBLE SHOOTING | ||
| Problem: | Possible Cause: | Solutions: |
| |
|
|
|
|
|
|
| Pilot will not light. | Air in Gas Lines. | Bleed air from Gas Line. |
| |
|
|
|
|
|
|
|
|
| Wrong Inlet Pressure. | Check Gas Line pressure (7” Nat., 11” L.P.). |
|
|
|
|
|
|
|
|
|
| Defective Spark | Replace Electrode if the Insulator is cracked or the Tip is |
|
|
|
| Electrode. | corroded. Verify that the Spark Gap between the Pilot and |
|
|
|
|
| the Electrodes correct. |
|
|
|
|
|
|
|
|
|
| Defective Piezo Wire. | Replace Piezo Wire if Insulation is damaged, broken, or |
|
|
|
|
| corroded. |
|
|
|
|
|
|
|
|
|
| Safety Interlock | Allow Thermocouple to cool until the mV drops below the |
|
|
|
| Function engaged. | hold - in requirements of the Safety Magnet (30 seconds or |
|
|
|
|
| less). Relight Pilot. |
|
|
|
|
|
|
|
| Pilot will not hold. | Wrong Inlet Pressure. | Check Gas Line pressure (7” Nat., 11” L.P.). |
| |
|
|
|
|
|
|
|
|
| Pilot Adjustment Screw | After the Pilot has been lit for approximately [3] min., and only |
|
|
|
| not adjusted properly. | the |
|
|
|
|
| Head, measure the voltage across TPTH and TP. This Open |
|
|
|
|
| Circuit voltage should be between 500mV and 750mV. Tune |
|
|
|
|
| the Pilot Adjustment Screw until the mV reading falls within |
|
|
|
|
| these parameters. |
|
|
|
|
| reading, Clockwise decreases it. Turn with a Wrench. |
|
|
|
|
|
|
|
|
|
| Thermocouple or | With the Thermocouple and |
|
|
|
| clean the upper 3/8” with a very fine Emery cloth. |
| |
|
|
| Film |
|
|
|
|
|
|
|
|
|
|
| Electrical Resistance | Using a very fine Emery cloth, clean the |
|
|
|
| too high. | and Thermocouple connections at the Valve. Tighten |
|
|
|
|
| Thermocouple into Valve, hand tight, adding a 1/4 turn |
|
|
|
|
| with a wrench. |
|
|
|
|
|
|
|
|
|
| Defective | Verify that the Thermocouple is not kinked or damaged. |
|
|
|
| Thermocouple. | Check |
|
|
|
| (mV Plus System) | be between 18mv and 28mv. If voltage is less than 14mv, |
|
|
|
|
| replace the Thermocouple. |
|
|
|
|
|
|
|
|
|
| Defective Thermo- | After the Pilot has been lit for approximately [3] min.,and only |
|
|
|
| generator. | the |
|
|
|
| (millivolt System) | Head, measure the voltage across TPTH and TP. This Open |
|
|
|
|
| Circuit voltage should be between 500mV and 750mV. Tune |
|
|
|
|
| the Pilot Adjustment Screw until the mV reading falls within |
|
|
|
|
| these parameters. |
|
|
|
|
| Clockwise decreases it. |
|
|
|
|
|
|
|
|
|
| Defective Safety Magnet | Verify operation of Safety Magnet in the following manner: |
|
|
|
| (mV Plus Systems). | (A) Depress and hold the Pilot Button. |
|
|
|
|
| (B) Verify |
|
|
|
|
| in previous Step. |
|
|
|
|
| (C) Reconnect Thermocouple to the Valve. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
02/01 | Page 54 |