Sapphire Audio DV425TR TROUBLE SHOOTING continued, Problem, Possible Cause, Solutions, Thermostat

Models: DV425TR

1 60
Download 60 pages 11.22 Kb
Page 56
Image 56
Thermostat/

DV425TR DIRECT VENT ROOM HEATER

TROUBLE SHOOTING (continued)

Problem:

Possible Cause:

Solutions:

Thermostat/

Excessive Wire

Make sure that all mV connections are made using wire of

Wall Switch

Resistance.

the proper size.

will not cycle

Valve Wired

The Thermo-generator leads must be connected to the

the Main

Incorrectly.

TPTH and TP connections of the Main Operator.

 

Thermostat Wires must be connected to

Burner (Cont.)

 

the TPTH and TP

Terminals of the Valve.

 

Main Burner lights

 

 

Main Operator Coil is

Verify electrical resistance

of the Main Operator the following

while in the

defective.

manner:

Pilot position.

 

(A) Remove ALL WIRES! from the Operator Head.

 

 

(B) With an Ohm meter, measure electric resistance between

 

 

the TP and TH Terminals. If the resistance does not fall

 

 

within specification, replace the Valve.

 

Debris on Seat of

Replace Valve.

 

Main Valve.

 

 

 

 

 

Main Seat blown out

Replace Valve.

 

as a result of exposing

 

 

an LPG Gas Valve to

 

 

an unregulated line

 

 

pressure in excess

 

 

 

 

02/01

Page 56

250-5533

Page 56
Image 56
Sapphire Audio DV425TR owner manual TROUBLE SHOOTING continued, Problem, Possible Cause, Solutions, Thermostat