DV425TR DIRECT VENT ROOM HEATER
LISTINGS AND CODE APPROVALS
The Dovre DV425TR Direct Vent Gas Appliance is listed to ANSI standard
SPECIFICATIONS
| Natural Gas | Propane |
| ||
Top Vent: |
|
|
Input Rate on "HI" (BTU/Hr) | 30,000 | 30,000 |
Input Rate on "LO (Btu/Hr) | 21,000 | 24,500 |
Max. Output (BTU/Hr)** | 25,000 | 24,600 |
Main Burner Orifice | .1065 (36 DMS) | .0635 (52 DMS) |
Rear Vent: |
|
|
Input Rate on "HI" (BTU/Hr) | 26,000 | 26,000 |
Input Rate on "LO" (BTU/Hr) | 18,000 | 20,000 |
Main Burner Orifice | .0960 (41 DMS) | .0595 (53 DMS) |
Min. Inlet Pressure (Inches W.C.) | 4.5" | 11" |
Max. Inlet Pressure (Inches W.C.) | 7.0" | 14" |
Manifold Pressure on "HI" (Inches W.C.) | 3.5" | 10" |
**Max Venting, Blower ON |
|
|
†This appliance is equipped for altitudes
NOTICES
Failure to follow all of the required installation procedures may result in property damage, bodily injury or even death. This appliance must be installed in accordance with all local codes, or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, or the Canadian Installation Code, CAN/CGA 149.
Manufactured Home or Mobile Home installation may occur only after the home is site located and must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not applicable, the Standard for Manufactured Home Installations, ANSI/INCSBCS A225.1, or Standard for Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4.
When installed, the appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Elecrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
The Dovre DV425TR is manufactured to operate on Natural Gas (NG), it is convertible to Liquid Propane (LP) when the manufacturer's conversion kit, part
All exhaust gases must be vented outside the structure of the
Notify your insurance company prior to connecting gas to this fireplace.
Installation requirements diagrammed and explained in this manual are grouped into segments for ease of procedure. While these requirements must be met fully, the order of installation may be subject to the procedure best suited for your specific placement of the fireplace.
NOTE: Illustrations throughout these instructions reflect typical installations and are for design purposes only. Actual installation may vary slightly due to individual design preferences. However, minimum and maxmum clearances must be maintained at all times.
The illustrations and diagrams used throughout these installation instructions are not drawn to scale.
02/01 | Page 3 |