Sapphire Audio DV425TR owner manual VERTICAL INSTALLATION, cont, Step

Models: DV425TR

1 60
Download 60 pages 11.22 Kb
Page 39
Image 39
Fig. 20

DV425TR DIRECT VENT ROOM HEATER

VERTICAL INSTALLATION, cont.

INSTALLATION INTO A CLASS A METAL CHIMNEY (USA ONLY)

Step 4.

Pass the flex pipe down through the center of the chimney system, and center the top adapter on the top of the chimney pipe. Drill four 1/8” (3.3mm) diameter holes through the top adapter, and into the chimney top. Ensure that you are drilling into the metal on the chimney. Twist lock the high wind termination cap (SDV #991) onto the top adapter (figures 20 and 21).

Fig. 20

High Wind

Termination Cap

Sheet Metal Scre

Drill (4) 1/8"

 

Diameter Holes

Fig. 21

Step 5.

Pull the flexpipe down through the ceiling support box, until it protrudes approximately 3" (76mm). Connect the flex pipe to the retro connector (SDV #909B), and attach with sheet metal screws.

Step 6.

Push the flex pipe back up into the ceiling support box, center the retro connector, and attach it to the support box with sheet metal screws.

Step 7.

The connection between the appliance and the retro connector may be completed with sections of direct vent pipe.

02/01

Page 39

250-5533

Page 39
Image 39
Sapphire Audio DV425TR owner manual VERTICAL INSTALLATION, cont, Step