Instructions for the installer
15.FINAL OPERATIONS
After replacing the nozzles, reposition the
Following adjustment to a gas other than the preset one, replace the gas adjustment label fixed to the appliance with the one corresponding to the new gas. This label is in the packet together with the nozzles.
15.1 Regulation of the hob burner minimum level for natural gas
Light the burner and turn it to the minimum position . Extract the gas tap knob and turn the adjustment screw at the side of the tap rod until the correct minimum flame is achieved.
Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). Repeat the operation on all the gas taps.
For models with valves, keep the knob at minimum level for about 1 minute to keep the flame lit and to activate the safety device.
15.2 Regulation of the hob burner minimum level for LPG
In order to adjust the minimum with LPG, the screw at the side of the tap rod must be turned clockwise all the way.
The bypass diameters for each individual burner are shown in paragraph “14.2 Burner and nozzle characteristics table". Once the regulation has been completed, restore the seal on the
15.3 Mounting the rear top upstand (where applicable)
•Loosen nuts B.
•Position the upstand above the top, taking care to align pins C with holes D.
•Secure the upstand to the top by tightening screws A.
15.4 Wall fixing
•Stretch out the chain attached to the cooker horizontally so that the other end touches the wall.
•Mark the wall in the position where the hole is to be drilled.
•Drill the hole, insert a wall plug and attach the chain.
•Move the cooker up against the wall.
21