Section 8 | Troubleshooting Guide | |||||
|
|
|
|
| ||
|
|
|
|
| ||
| PROBLEM | PROBABLE CAUSE | REMEDY | PAGE | ||
|
|
|
| REF. | ||
|
|
|
|
|
| |
1. | No product being | a. Power switch is in the “OFF” | a. Place power switch in the |
| 15 | |
| dispensed. | position. | “AUTO” position. |
|
|
|
|
| b. Improper mixing of product. | b. Carefully follow directions | - | - | - |
|
|
| for mixing product. |
|
|
|
|
| c. Inadequate mix in hopper. | c. Fill hopper with mix. |
| 16 | |
|
| d. Product frozen- up in freezing | d. Adjust viscosity adjustment |
| 10 | |
|
| cylinder. | accordingly. |
|
|
|
|
| e. Unit out on reset. | e. Place power switch in the |
| 10 | |
|
|
| “OFF” position. Press the |
|
|
|
|
|
| reset button. Return |
|
|
|
|
|
| control switch to “AUTO”. |
|
|
|
|
| f. Beater assembly is not | f. The power switch must be |
| 1 |
|
|
| rotating at all or | in “AUTO”. If beater is |
|
|
|
|
| counterclockwise. Control | rotating counterclockwise, |
|
|
|
|
| switch is not in “AUTO”. | call service technician to |
|
|
|
|
|
| correct rotation. |
|
|
|
|
| g. Unit is unplugged. | g. Plug in power cord. | - | - | - |
|
| h. Tripped circuit breaker or | h. Reset circuit breaker or | - | - | - |
|
| blown fuse. | replace fuse. |
|
|
|
|
|
|
|
|
| |
2. Unit will not operate in the | a. Unit unplugged at wall | a. Plug in power cord. | - | - | - | |
| “AUTO” or “WASH” mode. | receptacle. |
|
|
|
|
|
| b. Tripped circuit breaker or | b. Reset circuit breaker or | - | - | - |
|
| blown fuse. | replace fuse. |
|
|
|
|
| c. Unit out on reset. | c. Place the power switch in |
| 10 | |
|
|
| the “OFF” position. Press |
|
|
|
|
|
| the reset button. Return |
|
|
|
|
|
| control switch to “AUTO”. |
|
|
|
|
|
|
|
|
| |
3. | No compressor operation | a. Beater motor is out on | a. Place control switch in |
| 10 | |
| in the “AUTO” mode. | overload. | “OFF” position. Press the |
|
|
|
|
|
| reset button. Return |
|
|
|
|
|
| control switch to “AUTO”. |
|
|
|
|
| b. Condenser dirty A/C. | b. Clean condenser monthly. |
| 18 | |
|
|
|
|
|
| |
4. | Product too thick. | a. Inadequate mix in hopper. | a. Fill hopper with mix. |
| 16 | |
|
| b. Improper mixing of product. | b. Carefully follow directions | - | - | - |
|
|
| for mixing product. |
|
|
|
|
| c. The viscosity adjustment is | c. Adjust the viscosity control. |
| 10 | |
|
| set incorrectly. |
|
|
|
|
|
| d. The torque arm is not | d. Install the torque arm. |
| 13 | |
|
| installed. |
|
|
|
|
|
|
|
|
|
|
|
Troubleshooting Guide | 20 | Model 430 Torque |