Anritsu S251C manual TMA Gain Measurement After Calibration

Page 59

Chapter 4 Measurements

Step 8. Press the SYS key, then OPTIONS, then BIAS TEE to turn on the bias tee volt- age. The gain is the level change before and after the bias tee voltage is turned on.

Step 9. Press the AUTO SCALE key, or press the AMPLITUDE key to adjust the top and bottom scale, to display the gain level.

Step 10. Press the MARKER key and set marker set M1 to 834 MHz and marker M2 to 883 MHz.

REFERENCE LEVEL

GAIN MEASURED WITH

AFTER CALIBRATION

BIAS TEE ACTIVATED

 

Gain/Insertion Loss

2-PORT CAL

 

 

 

M1: .01 dB @ 833.68 MHz

 

 

M2: .00 dB @ 882.99 MHz

 

15

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

dB

 

 

 

 

 

 

 

 

 

 

 

0

Limit : 0.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M1

 

 

 

 

M2

 

-10

 

 

 

 

 

 

 

 

 

 

 

 

800

810

820

830

840

850

860

870

880

890

900

 

 

 

 

 

Frequency (800.0 - 906.0

 

 

 

Resolution: 130

CAL: ON(COAX)

Date: 06/13/2001

Time: 15:52:43

Gain/Insertion Loss

 

 

 

 

 

 

TMA

 

 

 

 

 

20

 

M1: 12.90 dB @ 833.68 MHz

M2: -.92 dB @ 882.99 MHz

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

0

Limit : 0.00

 

 

 

 

 

 

 

 

 

-10

 

 

 

 

 

 

 

 

 

 

 

-20

 

 

 

 

 

 

 

 

 

 

 

dB-30

 

 

 

 

 

 

 

 

 

 

 

-40

 

 

 

 

 

 

 

 

 

 

 

-50

 

 

 

 

 

 

 

 

 

 

 

-60

 

 

 

 

 

 

 

 

 

 

 

-70

 

 

 

 

M1

 

 

 

M2

 

 

 

 

 

 

 

 

 

 

 

 

800

810

820

830

840

850

860

870

880

890

900

 

 

 

 

Frequency (800.0 - 906.0 MHz)

 

 

Resolution: 130

CAL: ON(COAX)

Date: 06/13/2001

Time: 15:38:07

Figure 4-9. TMA Gain Measurement After Calibration

Marker M1 set at 834 MHz indicates the receive band of the tower mounted amplifier. The level above the 0 dB reference level is the gain of the TMA. Marker M2 set at 883 MHz in- dicates the transmit band of the amplifier where there is no gain.

Gain/Insertion Loss

TMA-S CELLULAR

(dB)

20

M1: 13.57 dB @ 836.82 MHz

 

 

 

 

 

10

 

 

 

 

 

 

 

 

Transmission

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

-10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-20

 

 

 

 

 

 

 

 

 

-30

 

 

 

 

 

 

 

 

 

-40

 

 

 

 

 

 

 

 

 

-50

 

 

 

 

 

 

 

 

 

-60

 

 

 

 

 

 

 

 

 

-70

 

 

 

 

M1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

750

775

800

825

850

875

900

925

 

 

 

 

Frequency (750.0 - 925.0 MHz)

 

 

Figure 4-10. TMA-S Gain Measurement

4-14

Image 59
Contents Site Master Model S251C Antenna Cable Analyzer Page Warranty Page Table of Contents Cable & Antenna Analysis Iii/iv Description Standard AccessoriesIntroduction Options Optional AccessoriesPerformance Specifications Description Site Master Performance Specifications 2 ESD Precautions Preventive MaintenanceAnnual Verification Anritsu Service Centers Chapter Functions and Operations Test Connector PanelActive Function Block Soft Keys Front Panel OverviewMode Function Hard KeysClear Keypad Hard KeysAuto MODE=FREQ FREQ/DIST Softkeys Soft KeysMODE=DTF FREQ/DIST Softkeys Functions and Operations Amplitude MODE=POWER Monitor Softkeys Power Monitor Menu OptionMODE=RF Source Softkeys RF Source MenuLimit Segment 1 Segment SYS Self Test SymbolsSelf Test Errors Error CodesERRORD2 Range ErrorsCharging the Battery in the Optional Charger Battery InformationCharging a New Battery Charging the Battery in the Site MasterBattery Life Battery Charge IndicatorImportant Battery Information Chapter Getting Started Power On ProcedureCalibration Select the Frequency or DistanceCalibration Calibration Procedure Single PortRF in Test Port RF OUT Test Port Calibration Procedure Dual PortSave and Recall a Display Setting the ScaleSave and Recall a Setup Recalling a Display Changing the Display Language Set the Distance and Cable TypeChanging the Units Printing a Screen PrintingPrinter Printer Switch SettingsUsing the Site Master Soft Carrying Case Using the Soft Carrying CaseLine Sweep Fundamentals One Port MeasurementsMeasurements Information Required for a Line SweepSystem Return Loss Measurement Typical Line Sweep Test Procedures2is an example of a typical system return loss trace Insertion Loss Measurement Procedure Cable Loss ModeType Attenuation dB/ft Length ft = Loss dB Procedure Return Loss Mode Procedure DTF-Return Loss Mode Distance-To-Fault DTF Transmission Line TestProcedure DTF-SWR Mode Antenna Subsystem Return Loss Test Vswr Introduction Two Port MeasurementsTMA-S TMA MeasurementsTMA Gain Measurement After Calibration TMA-DD 12. TMA-DD Gain Measurement TMA-D 14. TMA-D Gain Measurement 15. System Isolation Antenna to Antenna IsolationAntenna-to-Antenna Isolation Measurement Quency settings for common systems21/4-22 System Requirements FeaturesCommunication Port Setting InstallationDownloading Traces from the Site Master Using Software ToolsInterface Cable Installation Plot Properties Plot CaptureSaving Traces Trace Overlay or Plot OverlaySaving a Plot to a Spreadsheet Custom Cable ListPrinting Formats Creating a DatabaseAppendix a Reference Data Coaxial Cable Technical DataAppendix a Reference Data A-4 Examples Appendix B WindowingAppendix B Windowing B-4