Anritsu S251C manual Appendix a Reference Data

Page 75

Appendix A Reference Data

Table A-1.Coaxial Cable Technical Data (2 of 3)

 

 

 

Relative

Nominal

Nominal

Nominal

 

 

 

Attenuation

Attenuation

Attenuation

Manufacturer

Cable Type

Propagation

dB/m @

dB/m @

dB/m @

 

 

 

Velocity (Vf)

 

 

 

1000 MHz

2000 MHz

2500 MHz

 

 

 

 

 

 

 

 

 

 

Belden

RG214

0.659

0.292

N/A

N/A

 

 

 

 

 

 

Belden

RG223

0.659

0.535

N/A

N/A

 

 

 

 

 

 

Cablewave

HCC12-50J

0.915

0.087

0.126

0.137

 

 

 

 

 

 

Cablewave

HCC78-50J

0.915

0.041

0.061

0.066

 

 

 

 

 

 

Cablewave

HCC158-50J

0.95

0.022

0.031

0.033

 

 

 

 

 

 

Cablewave

HCC300-50J

0.96

0.015

N/A

N/A

 

 

 

 

 

 

Cablewave

HCC312-50J

0.96

0.013

N/A

N/A

 

 

 

 

 

 

Cablewave

HF 4-1/8” Cu2Y

0.97

0.01

N/A

N/A

 

 

 

 

 

 

Cablewave

HF 5” Cu2Y

0.96

0.007

N/A

N/A

 

 

 

 

 

 

Cablewave

HF 6-1/8” Cu2Y

0.97

0.006

N/A

N/A

 

 

 

 

 

 

Cablewave

FLC 38-50J

0.88

0.115

0.169

0.19

 

 

 

 

 

 

Cablewave

FLC 12-50J

0.88

0.072

0.11

0.134

 

 

 

 

 

 

Cablewave

FLC 78-50J

0.88

0.041

0.061

0.072

 

 

 

 

 

 

Cablewave

FLC 114-50J

0.88

0.033

0.05

0.059

 

 

 

 

 

 

Cablewave

FLC158-50J

0.88

0.025

0.038

0.042

 

 

 

 

 

 

Comscope

CR50 540 PE

0.88

0.069

0.103

0.116

 

 

 

 

 

 

Comscope

CR50 1070PE

0.88

0.037

0.055

0.064

 

 

 

 

 

 

Comscope

CR50 1873PE

0.88

0.022

0.0344

0.04

 

 

 

 

 

 

NK Cables

RF ½” -50

0.88

0.0757

0.112

0.127

 

 

 

 

 

 

 

NK Cables

RF ½”

-50 GHF

0.88

0.0757

0.112

0.127

 

 

 

 

 

 

 

NK Cables

RF ½”

-50 BHF

0.88

0.0757

0.112

0.127

 

 

 

 

 

 

NK Cables

RF 5/8”-50

0.88

0.0518

0.0768

0.087

 

 

 

 

 

 

NK Cables

RF 5/8”-50

0.88

0.0518

0.0768

0.087

GHF”

 

 

 

 

 

 

 

 

 

 

 

NK Cables

RF 5/8”-50

0.88

0.0518

0.0768

0.087

BHF”

 

 

 

 

 

 

 

 

 

 

 

NK Cables

RF 7/8”-50

0.88

0.0413

0.062

0.07

 

 

 

 

 

 

NK Cables

RF 7/8”-50

0.88

0.0413

0.062

0.07

GHF”

 

 

 

 

 

 

 

 

 

 

 

NK Cables

RF 7/8”-50

0.88

0.0413

0.062

0.07

BHF”

 

 

 

 

 

 

 

 

 

 

 

NK Cables

RF 1 5/8” -50

0.88

0.0248

0.038

0.044

 

 

 

 

 

 

NK Cables

RF 1 5/8” -50

0.88

0.0248

0.038

0.044

GHF”

 

 

 

 

 

 

 

 

 

 

 

NK Cables

RF 1 5/8” -50

0.88

0.0248

0.038

0.044

BHF”

 

 

 

 

 

A-2

Image 75
Contents Site Master Model S251C Antenna Cable Analyzer Page Warranty Page Table of Contents Cable & Antenna Analysis Iii/iv Standard Accessories IntroductionDescription Options Optional AccessoriesPerformance Specifications Description Site Master Performance Specifications 2 ESD Precautions Preventive MaintenanceAnnual Verification Anritsu Service Centers Chapter Functions and Operations Test Connector PanelActive Function Block Soft Keys Front Panel OverviewMode Function Hard KeysClear Keypad Hard KeysAuto MODE=FREQ FREQ/DIST Softkeys Soft KeysMODE=DTF FREQ/DIST Softkeys Functions and Operations Amplitude MODE=POWER Monitor Softkeys Power Monitor Menu OptionMODE=RF Source Softkeys RF Source MenuLimit Segment 1 Segment SYS Self Test SymbolsSelf Test Errors Error CodesERRORD2 Range ErrorsCharging the Battery in the Optional Charger Battery InformationCharging a New Battery Charging the Battery in the Site MasterBattery Life Battery Charge IndicatorImportant Battery Information Chapter Getting Started Power On ProcedureCalibration Select the Frequency or DistanceCalibration Calibration Procedure Single PortRF in Test Port RF OUT Test Port Calibration Procedure Dual PortSetting the Scale Save and Recall a SetupSave and Recall a Display Recalling a Display Set the Distance and Cable Type Changing the UnitsChanging the Display Language Printing a Screen PrintingPrinter Printer Switch SettingsUsing the Site Master Soft Carrying Case Using the Soft Carrying CaseLine Sweep Fundamentals One Port MeasurementsMeasurements Information Required for a Line SweepSystem Return Loss Measurement Typical Line Sweep Test Procedures2is an example of a typical system return loss trace Insertion Loss Measurement Procedure Cable Loss ModeType Attenuation dB/ft Length ft = Loss dB Procedure Return Loss Mode Procedure DTF-Return Loss Mode Distance-To-Fault DTF Transmission Line TestProcedure DTF-SWR Mode Antenna Subsystem Return Loss Test Vswr Introduction Two Port MeasurementsTMA-S TMA MeasurementsTMA Gain Measurement After Calibration TMA-DD 12. TMA-DD Gain Measurement TMA-D 14. TMA-D Gain Measurement 15. System Isolation Antenna to Antenna IsolationAntenna-to-Antenna Isolation Measurement Quency settings for common systems21/4-22 System Requirements FeaturesCommunication Port Setting InstallationUsing Software Tools Interface Cable InstallationDownloading Traces from the Site Master Plot Properties Plot CaptureSaving Traces Trace Overlay or Plot OverlaySaving a Plot to a Spreadsheet Custom Cable ListPrinting Formats Creating a DatabaseAppendix a Reference Data Coaxial Cable Technical DataAppendix a Reference Data A-4 Examples Appendix B WindowingAppendix B Windowing B-4