The Site Master menu-driven user interface is easy to use and requires little training. Hard keys on the front panel are used to initiate function-specific menus. There are four function hard keys located below the display, Mode, Frequency/Distance, Amplitude and Sweep.

There are seventeen keypad hard keys located to the right of the display. Twelve of the key- pad hard keys are dual purpose, depending on the current mode of operation. The dual pur- pose keys are labeled with one function in black, the other in blue.

There are also six soft keys that change function depending upon the current mode selec- tion. The current soft key function is indicated in the active function block to the right of the display. The locations of the different keys are illustrated in Figure 2-1.

Active

Function

Block

Soft Keys

Site Master S251C

1

2

START

AUTO

CAL

SCALE

3 4

SAVE RECALL

SETUP SETUP

5 6

LIMIT MARKER

7 8

SAVE RECALL

DISPLAY DISPLAY

9 0

ON PRINT

OFF.

MODE

FREQ/DIST

AMPLITUDE

SWEEP

ESCAPE

CLEAR

ENTER

RUN

HOLD +/-

SYS

Keypad

Hard

Keys

Function Hard Keys

Figure 2-1. Site Master Soft Keys

The following sections describe the various key functions.

2 - 2

Image 17
Contents Site Master Model S251C Antenna Cable Analyzer Page Warranty Page Table of Contents Cable & Antenna Analysis Iii/iv Description Standard AccessoriesIntroduction Options Optional AccessoriesPerformance Specifications Description Site Master Performance Specifications 2 ESD Precautions Preventive MaintenanceAnnual Verification Anritsu Service Centers Chapter Functions and Operations Test Connector PanelActive Function Block Soft Keys Front Panel OverviewMode Function Hard KeysClear Keypad Hard KeysAuto MODE=FREQ FREQ/DIST Softkeys Soft KeysMODE=DTF FREQ/DIST Softkeys Functions and Operations Amplitude MODE=POWER Monitor Softkeys Power Monitor Menu OptionMODE=RF Source Softkeys RF Source MenuLimit Segment 1 Segment SYS Self Test SymbolsSelf Test Errors Error CodesERRORD2 Range ErrorsCharging a New Battery Battery InformationCharging the Battery in the Site Master Charging the Battery in the Optional ChargerBattery Life Battery Charge IndicatorImportant Battery Information Chapter Getting Started Power On ProcedureCalibration Select the Frequency or DistanceCalibration Calibration Procedure Single PortRF in Test Port RF OUT Test Port Calibration Procedure Dual PortSave and Recall a Display Setting the ScaleSave and Recall a Setup Recalling a Display Changing the Display Language Set the Distance and Cable TypeChanging the Units Printing a Screen PrintingPrinter Printer Switch SettingsUsing the Site Master Soft Carrying Case Using the Soft Carrying CaseLine Sweep Fundamentals One Port MeasurementsMeasurements Information Required for a Line SweepSystem Return Loss Measurement Typical Line Sweep Test Procedures2is an example of a typical system return loss trace Insertion Loss Measurement Procedure Cable Loss ModeType Attenuation dB/ft Length ft = Loss dB Procedure Return Loss Mode Procedure DTF-Return Loss Mode Distance-To-Fault DTF Transmission Line TestProcedure DTF-SWR Mode Antenna Subsystem Return Loss Test Vswr Introduction Two Port MeasurementsTMA-S TMA MeasurementsTMA Gain Measurement After Calibration TMA-DD 12. TMA-DD Gain Measurement TMA-D 14. TMA-D Gain Measurement 15. System Isolation Antenna to Antenna IsolationAntenna-to-Antenna Isolation Measurement Quency settings for common systems21/4-22 System Requirements FeaturesCommunication Port Setting InstallationDownloading Traces from the Site Master Using Software ToolsInterface Cable Installation Plot Properties Plot CaptureSaving Traces Trace Overlay or Plot OverlaySaving a Plot to a Spreadsheet Custom Cable ListPrinting Formats Creating a DatabaseAppendix a Reference Data Coaxial Cable Technical DataAppendix a Reference Data A-4 Examples Appendix B WindowingAppendix B Windowing B-4